INSTALLATION

AIR INTAKE COVER

The pedestal is equipped with an air intake cover (lo- cated at the top front of the pedestal). The air intake cover should be adjusted to the open position if outside combustion air is NOT provided. If outside combustion air is provided, adjust to the closed position (see illustra- tion to the right).

Air Intake

Cover

OpenClosed

Pedestal

Front

OUTSIDE AIR

In all manufactured (mobile) homes and in many site built residences (subject to local code), a stove may be required to use outside air for combustion. A 5 ¼” (133

mm)square outside air floor duct is available through your dealer.

Stove

Outside

 

Air Floor

 

Duct

Floor Protector

This stove can take in outside air directly through the base. This type installation requires a hole through the floor protector and the use of outside air floor duct (cata- log # 14M67) to penetrate into the air space below the home. When outside air is hooked up, the Air Intake Cover must be adjusted to the closed position (see Air Intake Cover section on this page).

NOTE: Because the base sits 1” (25.4 mm) off the floor, the outside air floor duct can be positioned along the front to rear center line under the pedestal, but as close to the opening in the base as location permits. The air duct opening must be protected from any possible ob- struction including loose floor insulation.

MANUFACTURED (MOBILE) HOME REQUIREMENTS This stove is certified as a Room Heater, Solid Fuel Type and may be used in Manufactured Housing providing the following requirements are followed:

An outside air inlet must be provided for combustion and be unrestricted while unit is in use.

WARNING: DO NOT INSTALL IN SLEEPING ROOM.

Regulations require that the appliance must be se- cured to the floor and grounded to the chassis. See Securing the Stove to the Floor (and) Grounding Stove.

Required venting is 6” (152 mm) diameter Type L- Vent connector pipe with listed factory-built 103HT chimney suitable for use with solid fuels or a code approved masonry chimney. Approved brands of fac- tory built chimney are listed in this manual. A rain cap and spark arrestor is required (see Clearances, pages 6 & 7).

CAUTION: THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL, AND CEIL- ING/ROOF MUST BE MAINTAINED.

The chimney must provide for a section joint so that any parts extending above 13’ 6” (411 cm) from ground level can be removed for transportation of the mobile dwelling.