Functions
Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
• Room temperature sensor. (THERMISTOR)
Room temperature control
• Maintains the room temperature in accordance with the Setting Temp.
Starting Current Control
• Indoor fan is delayed for 5 sec at the starting.
Time Delay Safety Control
• Restarting is inhibited for approx. 3 minutes.
Indoor Fan Speed Control
• High, Med, Low, CHAOS
Operation indication Lamps (LED)
Signal Receptor
Receives the signals from the remote control.(Signal receiving sound: two short beeps or one long beep.)
Operation Indication Lamps |
|
|
On/Off | : Lights up during the system operation. |
|
Sleep Mode | : Lights up during Sleep Mode Auto operation. |
|
Timer | : Lights up during Timer operation. |
|
Defrost Mode | : Lights up during Defrost Mode or |
|
| Hot Start operation.(Heat pump model only) |
|
Outdoor unit operation | : Lights up during outdoor unit operation. |
|
| (Cooling model only) | Operation indication lamps |
|
|
Soft Dry Operation Mode
• Intermittent operation of fan at low speed.
Sleep Mode Auto Control
•The fan is switched to low(Cooling), med(Heating) speed.
•The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
Natural Air Control by CHAOS Logic
•The fan is switched to intermittent or irregular operation
•The fan speed is automatically switched from high to low speed.
Airflow Direction Control
•The louver can be set at the desired position or swing up and down automatically.
Defrost(Deice) control (Heating)
•Both the indoor and outdoor fan stops dur- ing defrosting.
•The indoor fan stops until the
evaporator pipe temperature will be reached at 28°C.