Functions

Indoor Unit

Operation ON/OFF by Remote controller

Sensing the Room Temperature

• Room temperature sensor. (THERMISTOR)

Room temperature control

• Maintains the room temperature in accordance with the Setting Temp.

Starting Current Control

• Indoor fan is delayed for 5 sec at the starting.

Time Delay Safety Control

• Restarting is inhibited for approx. 3 minutes.

Indoor Fan Speed Control

• High, Med, Low, CHAOS

Operation indication Lamps (LED)

Signal Receptor

Receives the signals from the remote control.(Signal receiving sound: two short beeps or one long beep.)

Operation Indication Lamps

 

 

On/Off

: Lights up during the system operation.

 

Sleep Mode

: Lights up during Sleep Mode Auto operation.

 

Timer

: Lights up during Timer operation.

 

Defrost Mode

: Lights up during Defrost Mode or

 

 

Hot Start operation.(Heat pump model only)

 

Outdoor unit operation

: Lights up during outdoor unit operation.

 

 

(Cooling model only)

Operation indication lamps

 

 

Soft Dry Operation Mode

• Intermittent operation of fan at low speed.

Sleep Mode Auto Control

The fan is switched to low(Cooling), med(Heating) speed.

The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.

Natural Air Control by CHAOS Logic

The fan is switched to intermittent or irregular operation

The fan speed is automatically switched from high to low speed.

Airflow Direction Control

The louver can be set at the desired position or swing up and down automatically.

-4-

Defrost(Deice) control (Heating)

Both the indoor and outdoor fan stops dur- ing defrosting.

Hot-start Control (Heating)

The indoor fan stops until the

evaporator pipe temperature will be reached at 28°C.