2.Product does not operate at all.
(* Refer to Electronic Control Device drawing and Schematic diagram.)
Turn off Main Power
(After 10 seconds)
Turn on Main Power
Does "beeping" sound is made from the Indoor Unit?
NO
Check the voltage of power(About AC 208V/AC230V, 60Hz)
•Main power's voltage
•Voltage applied to the unit
•Connecting method of Indoor/Outdoor connecting cable
•Check PWB Ass'y(Outdoor unit)
-Fuse
-Pattern damage
-Varistor(ZNRI)
Check the connection housing for contacting
•Connector related to
•Connector related to
•Connector contacting of Outdoor Fan/Compressor
•Display PWB Ass'y Check
•Connector related to
YES
Primarily, the operating condition of Micom is OK.
Check each load(Indoor/Outdoor Fan Motor, Compressor, Stepping Motor) and contacting condition of related connector(including connecting cable of Indoor/Outdoor Unit)
PCB Board Operation Check
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Items |
|
|
| Content |
|
|
| Remedy |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| • Power Transformer |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| (Outdoor unit) |
|
|
|
|
|
|
|
|
|
|
| |
| - Input Voltage |
|
| - About AC208V/230V±10% - Check the power voltage |
|
|
| • Replace Trans |
|
| |||
| - Output Voltage |
|
| - About AC17±3V |
|
|
|
|
|
| |||
| • IC2(7812) Output |
|
| • DC +12V |
|
|
| • Replace IC2 |
|
| |||
| (Indoor/Outdoor unit) |
|
|
|
|
|
|
|
|
|
|
| |
| • IC3(7805) Output |
|
| • DC +5V |
|
|
| • Replace IC3 |
|
| |||
| (Indoor/Outdoor unit) |
|
|
|
|
|
|
|
|
|
|
| |
| • IC4(KIA7036, Reset IC) |
|
| • Voltage of Outdoor unit Micom No. 8, |
|
|
| • Replace faulty parts |
|
| |||
| OSC01B(4MHz) |
|
| Voltage of Indoor unit Micom No. 43 and soldering |
|
|
|
|
|
| |||
| (Indoor/Outdoor unit) |
|
| condition |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
- 43 -