4. checking the Drainage and forming the pipings

1) Checking the drainage

1. To check the drainage.

Pour a glass of water on the evaporator.

Ensure the water flows through the drain hose of the indoor unit without any leakage and goes out the drain exit.

2. Drain piping

The drain hose should point downward for easy drain flow.

Downward slope

Do not make drain piping.

 

Do not raise

 

Accumulated

 

 

 

 

 

drain water

 

 

 

 

 

 

 

Tip of drain hose

 

 

 

 

Air

 

Less than

 

 

 

 

 

dipped in water

 

 

 

 

 

50mm gap

 

 

 

 

 

 

Water

 

Water

Waving

Water

 

 

leakage

 

leakage

leakage

Ditch

 

 

 

 

 

 

 

 

 

 

2) Form the piping

1.Form the piping by wrapping the connecting por- tion of the indoor unit with insulation material and secure it with two kinds of vinyl tapes.

If you want to connect an additional drain hose, the end of the drain outlet should be routed above the ground. Secure the drain hose appropriately.

2.In cases where the outdoor unit is installed below the indoor unit perform the following.

Tape the piping, drain hose and connecting cable from down to up.

Secure the tapped piping along the exterior wall using saddle or equivalent.

Seal small openings around pipings with a gum type sealer.

Taping

Drain hose

Pipings

Connecting cable

Trap is required to prevent water from entering into electrical parts.

3.In cases where the Outdoor unit is installed above the Indoor unit perform the following.

Tape the piping and connecting cable from down to up.

Secure the taped piping along the exterior wall. Form a trap to prevent water entering the room.

Fix the piping onto the wall by saddle or equivalent.

Seal a small opening around the pipings with gum type sealer.

Trap

Trap

-26-

Page 26
Image 26
LG Electronics LSC183VMA Checking the Drainage and forming the pipings, Checking the drainage, Form the piping