Installation

1. Installation of indoor, Outdoor unit

Read completely, then follow step by step.

1) Select the best location

1. Indoor unit

Do not have any heat or steam near the unit.

Select a place where there are no obstacles in front of the unit.

Make sure that condensation drainage can be con- veniently routed away.

Do not install near a doorway.

Ensure that the space around the left and right of the unit is more than 50cm(19.7”). The unit should be installed as high on the wall as possible, allowing a minimum of 10cm(3.9”) from ceiling.

Use a stud finder to locate studs to prevent unnec- essary damage to the wall.

More than

1. Installation of indoor, Outdoor unit10cm(3.9") More than

50cm(19.7")

More than

More than

50cm(19.7")

2m(6.6ft)

 

CAUTION

Install the indoor unit on the wall where the height from the floors more than 2m(6.6ft).

Rooftop Installations:

If the outdoor unit is installed on a roof structure, be sure to level the unit. Ensure the roof structure and anchoring method are adequate for the unit loca- tion. Consult local codes regarding rooftop mount- ing.

2) Piping length and elevation

 

Capacity

 

 

Pipe Size

Standard

Max.

 

Max.

Additional

 

 

 

 

 

 

 

Length

Elevation

 

length

Refrigerant

 

(Btu/h)

 

GAS

 

LIQUID

(m)

B (m)

 

A (m)

(g/m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18K

 

5/8"

 

1/4"

7.5

15

 

 

30

20

 

 

 

(24.6ft)

(49.2ft)

 

(98.4ft)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor unit

Indoor unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor unit

 

 

 

 

B

 

 

B

 

 

Outdoor unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. Outdoor unit

If an awning is built over the unit to prevent direct sunlight or rain exposure, make sure that heat radia- tion from the condenser is not restricted.

Ensure that the space around the back and sides is more than 10cm(3.9”).

The front of the unit should have more than 70cm(27.5”) of space.

Do not place animals and plants in the path of the warm air.

Take the air conditioner weight into account and select a place where noise and vibration are mini- mum.

Select a place so that the warm air and noise from the air conditioner do not disturb neighbors.

 

More than 60cm(24")

More than 10cm(3.9")

More than 10cm(3.9")

More than 70cm(28")

More

than 60cm(24")

 

Outdoor unit

Oil trap

A

 

Indoor unit

 

B

In case more than 5m(16.4ft)

CAUTION

Capacity is based on standard length and maximum allowance length is on the basis of reliability.

Oil trap should be installed every 5~7 meters(16.4~23ft).