7. TROUBLESHOOTING
7-1.BEFORE PERFORMING SERVICE
Be careful of electric shock or disconnecting the parts while troubleshooting.
Voltage of each terminal in
7-2.QC TEST MODE.
Pressing Option1, and Spin button simultaneously.
Power supply on with pressing upper two button.Then buzzer sound twice.
Press the Start/Pause button as follows.
Press the Start/Pause button more 4 times until stop spinning
Pressing number of | Checking Point | Display Status | |||
Start/Pause | button | ||||
|
| ||||
None |
|
| All lamps turn on |
| |
|
|
|
|
| |
1 time |
|
| Clockwise spin (right) | Drum rpm (About 40~50) | |
|
|
|
|
| |
2 times |
|
| Low speed Spin | Drum rpm (About 53~65) | |
|
|
|
|
| |
3 times |
|
| High speed Spin | Drum rpm (About 140~160) | |
|
|
|
|
| |
4 times |
|
| Inlet valve for prewash operation | Water level frequency (25~65) | |
|
|
|
|
| |
5 times |
|
| Inlet valve for mainwash operation | Water level frequency (25~65) | |
|
|
| |||
|
| Hot inlet valve in case of hot water fill | |||
|
|
|
| ||
|
|
|
|
| |
6 times |
|
| Inlet valve for mainwash operation | Water level frequency (25~65) | |
|
|
|
|
| |
7 times |
|
| Counterclockwise spin (left) | Drum rpm (About 40~50) | |
|
|
|
|
| |
8 times |
|
| Heater is in operation for 3 sec. | Water temperature | |
|
|
|
|
| |
9 times |
|
| Circulation pump operation | Water level frequency | |
|
|
|
|
| |
10 times |
|
| Draining pump operation | Water level frequency | |
|
|
|
|
| |
11 times |
|
| Auto off operation |
| |
|
|
|
|
|
7-3.HOW TO KNOW THE WATER LEVEL FREQUENCY
Press the Rinse and Spin button simultaneously.
The digits means water level frequency
ex) 241 : Water level frequency = 241
13