LG Electronics WD(M)-12220(5)FD, 16221FD Error Symptom, Cause, MAIN PWB ASSEMBLY is out of order

Models: 16221FD 10220(5)FDB(N)

1 36
Download 36 pages 20.86 Kb
Page 16
Image 16
ERROR SYMPTOM

 

ERROR SYMPTOM

CAUSE

 

 

 

8

 

• MAIN PWB ASSEMBLY is out of order

CURRENT

Replace the MAIN PWB ASSEMBLY

 

 

ERROR

• Winding in the STATOR ASSEMBLY is short-circuited.

 

 

Replace the STATOR ASSEMBLY

 

 

 

 

 

• The connector (3-pin, male, white) in the LEAD WIRE ASSEMBLY

9

LOCK

is not connected to the connector (3-pin, female, white) of

ERROR

STATOR ASSEMBLY.

 

 

 

Reconnect or repair the connector

The electric contact between the connectors 3-pin, male, white in the LEAD WIRE ASSEMBLY and 4-pin, female, natural in the MAIN PWB ASSEMBLY is bad or unstable.

• MAIN PWB ASSEMBLY is out of order Reconnect or repair the contact in the connector

The LEAD WIRE ASSEMBLY between the STATOR ASSEMBLY and MAIN PWB ASSEMBLY is cut (open circuited).

Manual background Repair the damaged (open-circuited) the LEAD WIRE ASSEMBLY

The hall sensor is out of order/defective.

Replace the STATOR ASSEMBLY

15

Page 16
Image 16
LG Electronics WD(M)-12220(5)FD, WD(M)-14220(5)FD, WD(M)-10220(5)FD Error Symptom, Cause, MAIN PWB ASSEMBLY is out of order