Thermocouple Probe

Remove thermocouple leads from the temperature

 

 

control board, and measure the millivolt output of

 

 

these leads. Refer to charts on page 25 in the

 

 

adjustment section for proper readings.

 

Temperature Control

Turn temperature control dial to full "on" position.

 

 

NOTE: Thermocouple must be connected. Measure

 

 

for 120 VAC across terminals "N.O." and Com., if

 

 

voltage is not present; replace control.

 

Solenoid Valve

If voltage is present at terminals "N.O." and Com.,

 

 

check for voltage at solenoid valve. If voltage is

 

 

present, listen for valve to open and close. Also,

 

 

check for opens and shorts in coil. If solenoid valve is

 

 

defective, replace.

Intermittent Heating

AS FOLLOWS

Both the main fan motor and burner blower motor are

 

 

equipped with thermo-protection and will cease to

 

 

operate when not cooled properly. This can cause

 

 

the units to cycle on and off intermittently. Also, most

 

 

of the problems listed under "oven will not heat" can

 

 

cause intermittent failures.

For continuing intermittent problems, a series of test lights may be made and installed in the ovens. The lights will allow the customer to advise the service technician a trouble code when the oven fails

The lights should be connected in the following manner:

Light#1 attached in 120 VAC line after oven fan switch.

Light #2 attached after 120 VAC contacts of oven motor centrifugal switch

Light #3 in 24 VAC Burner Transformer Secondary.

Light #4 in 24 VAC at terminal #6 of Ignition control valve.

Light #5 in 24 VAC at terminal #3 of Ignition control valve.

Light #6 in 24 VAC at terminal #1 of Ignition control valve.

CODE:

All lights off - lights of main power, main fan off, oven fan switch out.

1 on 2 off 3 off 4 off 5 off 6 off - Oven Motor Centrifugal Switch open

1 on 2 on 3 on 4 off 5 off 6 off - Burner Motor Centrifugal Switch bad.

1 on 2 on 3 on 4 on 5 0ff 6 off - Ignition Control bad

1 on 2 on 3 on 4 on 5 on 6 off - Pilot Shield missing or warped, no flame rectification, Pilot

-Orifice plugged, or Gas Control Valve bad.

1on 2 on 3 on 4 on 5 on 6 on - Unit still not working Main Orifice plugged, Gas Valve bad,

-Temperature Control bad.

-However, Main Orifice would not be intermittent problem.

Conveyor will not run

Voltage Supply

Check incoming voltage supply at line 1 to neutral.

 

 

There should be a voltage reading of 120 VAC. If not

 

 

present, check breakers.

 

3 Amp Fuse

This control fuse is located on the front panel.

 

 

Replace if defective.

 

Fuseholder

Check and/or replace.

 

Fan Switch

See procedure for checking on page 11.

 

Speed Adjustment

This is a 0 to 10 K ohm, 1 turn potentiometer. With

 

Potentiometer

power off, remove the black and white pot leads from

 

 

the motor control board at terminals P1, P2. Place the

 

 

meter leads on the black lead (P2) and on the white

 

 

lead (P1). Rotating the pot., slowly, from low to high,

 

 

the meter reading should show an even transition

 

 

from 0 to 10K ohms ± 5%. There should be no dead or

 

 

open spots through out the 1 turn of the pot. Check

 

 

both leads to ground. There should be no continuity to

 

 

ground. If any of the above checks fail, replace the

 

 

pot.