Lincoln Electric IM491-B manual Single Voltage

Models: IM491-B

1 40
Download 40 pages 57.4 Kb
Page 34
Image 34

INPUT SUPPLY CONNECTION DIAGRAM

FOR SINGLE VOLTAGE MACHINE.

NOTE: MACHINES ARE SHIPPED FROM FACTORY CONNECTED

GND.

 

 

 

LINK

 

 

 

 

 

 

 

 

FOR 575 VOLTS

 

 

 

 

 

 

575 V.,60HZ.

 

LINK POSITIONS

 

 

U

U

T3

9

 

 

 

 

 

 

 

 

 

 

 

 

 

11

6

 

 

V

V

5

 

 

 

 

 

 

 

 

 

8

10

12

 

 

 

 

 

 

 

W

W

 

T1

 

 

 

 

4

1.

CONNECT U, V, & W INPUT SUPPLY LINES TO STUDS

 

T2

 

 

 

MARKED U, V, & W ON RECONNECT PANEL.

 

 

 

7

 

 

 

 

 

2.

CONNECT TERMINAL MARKED

TO GROUND PER

 

 

 

 

NATIONAL ELECTRICAL CODE.

 

 

 

 

3.REMOVE HEX NUTS AND POSITION LINKS AS SHOWN. REPLACE AND TIGHTEN ALL HEX NUTS.

THE LINCOLN ELECTRIC CO., CLEVELAND, OHIO U.S.A.

1-14-94B

 

 

 

 

 

M17491

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIGURE 1- SINGLE VOLTAGE

INPUT SUPPLY CONNECTION DIAGRAM FOR TRIPLE VOLTAGE MACHINE.

NOTE: MACHINES ARE SHIPPED FROM FACTORY CONNECTED

FOR 440 (OR 460) VOLTS

GND.

440V.,50HZ.

460V.,60HZ.

{

U

V

W

 

LINK POSITIONS

LINK

U

T3

9

 

 

 

 

 

11

6

 

V

5

 

 

 

 

 

 

 

12

 

 

8

 

 

 

10

 

T1

W

4

 

 

 

 

 

T2

 

 

 

 

 

7

 

380 V.,50HZ.

 

LINK POSITIONS

LINK

GND.

{

U

U

9

 

 

 

 

 

T3

 

 

 

 

 

11

 

 

 

V

V

6

 

 

 

5

12

 

 

 

 

 

 

 

 

8

 

T1

 

 

W

10

 

 

 

W

 

 

 

 

4

 

 

 

 

T2

 

7

1. CONNECT U, V, & W INPUT SUPPLY LINES TO STUDS

 

220 V.,50HZ.

 

LINK POSITIONS

LINK

 

230 V.,60HZ.

 

MARKED U, V, & W ON RECONNECT PANEL.

 

 

 

 

 

 

 

 

GND.

{

 

 

T3

 

 

 

 

 

U

U

 

 

2. CONNECT TERMINAL MARKED

TO GROUND PER

 

 

 

 

9

 

 

 

 

 

 

 

 

NATIONAL ELECTRICAL CODE.

 

 

 

 

 

11

6

 

 

 

 

V

V

 

 

 

 

 

 

 

 

5

12

 

 

 

 

 

 

 

 

3. REMOVE HEX NUTS AND POSITION LINKS AS SHOWN.

 

 

W

8

10

T1

 

REPLACE AND TIGHTEN ALL HEX NUTS.

 

 

 

W

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

T2

7

 

THE LINCOLN ELECTRIC CO., CLEVELAND, OHIO U.S.A.

5 - 2 8 - 9 3

 

 

 

 

M16437

 

 

 

 

 

 

 

FIGURE 1- DUAL & TRIPLE VOLTAGE

– 34 –