INSTALLATIONA-1

TECHNICAL SPECIFICATIONS – IDEALARC® SP-255

INPUT – SINGLE PHASE ONLY

Standard Voltage/Frequency

208/230/60 Hz

230/460/575 Hz

Input Current (@ Max Rated Output)

53/49 Amps

50/25/20 Amps

Duty Cycle 35% 60% 100%

Welding Current Range

30-250 Amps

RATED OUTPUT

Amps

250Amps

200Amps

145Amps

OUTPUT

Maximum Open Circuit Voltage

40 Volts

Volts at Rated Amperes

26Volts

28Volts

26Volts

Wire Speed Range

50-600 IMP (1.27-15.2 m/min)

RECOMMENDED INPUT CABLE AND FUSE SIZES

 

 

 

75C Copper Wire

75C Copper Wire

 

 

 

 

in Conduit

in Conduit

 

Input

Fuse or

Input Ampere

AWG (IEC)

AWG (IEC)

 

Voltage/

Breaker Size

Rating on

Sizes

Sizes

 

Frequency

(Super Lag)

Nameplate

For lengths

For lengths

Ground Wire

 

 

 

up to 100 ft.

exceeding 100 ft.

 

 

 

 

 

 

 

208

60

53

8 (10 mm2)

6 (16 mm2)

#10 (6 mm2)

230

60

50

10 (6 mm2)

8 (10 mm2)

#10 (6 mm2)

460

30

25

14 (2.5 mm2)

12 (4 mm2)

#10 (6 mm2)

575

25

20

14 (2.5 mm2)

12 (4 mm2)

#10 (6 mm2)

 

 

 

 

 

 

PHYSICAL DIMENSIONS

Height

Width

Depth

Weight

28.2 in

18.8 in

40.1 in

222 Ibs

719 mm

480 mm

1019 mm

101 kg

 

 

 

 

OPERATING TEMPERATURE

STORAGE TEMPERATURE

-20° C TO 40°C

±40°C

AUG 95 IDEALARC SP-255

Page 9
Image 9
Lincoln Electric manual INSTALLATIONA-1, Technical Specifications Idealarc SP-255