Lincoln Electric SP-255 manual ACCESSORIESC-3, Disabling Spool GUN

Models: SP-255

1 53
Download 53 pages 22.63 Kb
Page 31
Image 31

ACCESSORIESC-3

TYPICAL STITCH KEY PRESS

SEQUENCE

Spool screen is displayed prior to pressing Stitch key. Stitch key is pressed, Stitch timers are activated and the display changes to Stitch screen. Stitch ON and OFF timers can now be adjusted using the center and right arrow keys. Once the timers have been set, pressing the Stitch key again returns the display to the original Spool screen with the Stitch timer status indicated in the bottom left corner.

memory 4 is recalled and appears on the display. This whole cycle is repeatable as long as the unit remains in Toggle mode.

TOGGLE KEY

The first time this key is pressed it turns on toggle mode and recalls the setup in memo- ry 4. This mode allows you to toggle between the setups in memory 4 and mem- ory 5. Each time the key is pressed, it alter- nates between the two memories. The tog- gle screen displays the memory number the current setup was recalled from, indicates spool (SPOL:) mode, displays percentage of wire feed speed, and set arc voltage. The cursor underlines the memory number cur- rently selected.

TYPICAL TOGGLE KEY PRESS

SEQUENCE

Spool screen is displayed prior to pressing Toggle key. Toggle key is pressed, memory 4 is recalled and appears on the display. The unit is now in toggle mode. Pressing the Toggle key again “toggles” the unit, and

DISABLING SPOOL GUN

When the Spool Gun Adapter box transfer switch is set to FEEDER Gun position, the display will flash between these two mes- sages:

Pressing the Process key will return you to the last process entered before the Spool gun was attached.

IDEALARC SP-255

Page 31
Image 31
Lincoln Electric SP-255 manual ACCESSORIESC-3, Disabling Spool GUN