TROUBLESHOOTING AND REPAIR |
Observe Safety Guidelines detailed in the beginning of this manual.
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
PROBLEMS
(SYMPTOMS)
The weld output varies abnormally. Auxiliary voltage is normal. (continued)
POSSIBLE AREAS OF MISADJUSTMENT(S)
OUTPUT PROBLEMS
RECOMMENDED
COURSE OF ACTION
Examine polarity switch for poor electrical connections and damaged or burned contacts. Replace if necessary. If polarity switch contacts have excessive arc damage, check the 500 Ohm resistor.
Perform the Exciter Rotor
Resistance and Ground Test.
Perform the Shunt Field Coil
Resistance and Ground Test.
Check the Generator brush rocker position; perform the
Rocker Adjustment Procedure if necessary.
Return to Section TOC
Return to Master TOC
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call