F-70

TROUBLESHOOTING AND REPAIR

F-70

ENGINE ALTERNATOR TEST (continued)

FIGURE F.25 – ALTERNATOR CODE 10856

#237

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

GROUND

PROCEDURE

1.Open the right side cover, on the radiator end of the SAE-400 machine.

WARNING: Secure the door in the open position using the door restraint system. If the machine does not have a door restraint system, remove the door(s) or securely restrain them to prevent them from falling closed.

2.Locate the engine alternator (See Figure F.25 & Figure F.26)

#224

Chassis ground to the alternator flash/sense lead, (Lead #224 for cod 10856) (Lead #59 for codes 11199 and 11408) the meter should read 0 volts.

Run/stop switch on:

Chassis ground to the flash/sense lead, (Lead #224 for cod 10856) (Lead #59 for codes 11199 and 11408) the meter should read 11.5 to 12.9 Volts DC during first 30 seconds of operation. (This time may be 60 seconds on some models.)

Return to Section TOC

Return to Master TOC

3.Check voltage as follows:

4.Run/stop switch off:

Chassis ground to the B+ terminal of the alterna- tor, (Lead #237 for code 10856) (Lead #51 for codes 11199 and 11408) the meter should read battery voltage.