TROUBLESHOOTING AND REPAIR | ||||
Observe Safety Guidelines detailed in the beginning of this manual. |
|
| ||
|
|
|
|
|
PROBLEMS |
| POSSIBLE AREAS OF | RECOMMENDED |
|
(SYMPTOMS) |
| MISADJUSTMENT(S) | COURSE OF ACTION |
|
|
|
|
|
|
|
| OUTPUT PROBLEMS |
|
|
The weld output is considerably |
| Examine polarity switch for poor | ||
less than indicated on the dials. |
| electrical connections and |
| |
Auxiliary voltage is normal. |
| damaged or burned contacts. |
| |
(continued) |
|
| Replace if necessary. If polarity | |
|
| switch contacts have excessive | ||
|
|
| ||
|
|
| arc damage, check the 500 Ohm | |
|
|
| resistor. |
|
|
|
| Verify that the rocker is |
|
|
|
| positioned correctly, according to | |
|
|
| the factory drill mark. If |
|
|
|
| necessary, perform the Rocker | |
|
|
| Adjustment Procedure. |
|
|
|
|
| |
The weld output is considerably | If a remote current control is | Verify that the rocker is |
| |
higher than indicated on the | being used, try switching to local | positioned correctly, according to | ||
dials. Auxiliary voltage is | control. The remote current | the factory drill mark. |
| |
normal. |
| control may be faulty. | Perform the Dead Short, First |
|
|
|
|
| |
|
|
| Step, and Open Reactor Tests. | |
|
|
| Perform the Exciter Rotor |
|
|
|
| Resistance and Ground Test. |
|
|
|
| Perform the Shunt Field Coil |
|
|
|
| Resistance and Ground Test. |
|
|
|
| Perform the Rocker Adjustment | |
|
|
| Procedure. |
|
|
|
|
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call