Linear RE-1 Wiring Diagram, Typical Gate Installation Wiring, Typical Door Installation Wiring

Models: RE-1

1 32
Download 32 pages 57.38 Kb
Page 6
Image 6
WIRING DIAGRAM

WIRING DIAGRAM

TYPICAL

GATE INSTALLATION WIRING

RELAY RATING: 3 AMPS AT 30 VOLTS AC OR DC MAXIMUM

RE-1

TELEPHONE ENTRY

SYSTEM

TRANSFORMER

TRANSFORMER

BATTERY NEGATIVE

BATTERY POSITIVE

SENSE #1

OPEN #1

SENSE #2

OPEN #2

 

 

 

RELAY

 

 

RELAY

 

 

 

#1

 

 

#2

 

 

N.O.

COM

N.C.

N.O.

COM

N.C.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CASE

GROUND

GATE

OPEN OPERATOR

16VAC 20 VA

TRANSFORMER

COMMON KEYPAD CLK KEYPAD DVAL KEYPAD DAT 0 KEYPAD DAT 1 KEYPAD GND KEYPAD PWR

RING

TIP

RING

TIP

EARTH

HOUSE TELCO

TO HOUSE

PHONES

TO TELCO

LINE

TYPICAL 10' MAXIMUM

WIRE RUN

RING

HOUSE

 

TIP

 

 

 

RING

RE-1

TELEPHONE

TIP

HOUSE

RING

 

BYPASS

RE-1

MODULE

TIP

TELCO

EARTH

 

 

RING

 

GROUND

TELCO

 

TIP

 

 

 

10' MAXIMUM

GROUND

STAKE

GROUND

STAKE

WIRE RUN

TYPICAL

DOOR INSTALLATION WIRING

NOTE: A MAGNETIC LOCK AND DOOR STRIKE ARE BOTH SHOWN, TYPICALLY ONLY ONE IS USED

NOTE: DO NOT POWER

THE LOCKING DEVICE FROM THE RE-1 TRANSFORMER

RELAY RATING:

 

 

 

RELAY

 

 

 

 

RELAY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 AMPS AT

 

 

 

#1

 

 

 

 

#2

 

 

 

 

 

 

 

 

 

30 VOLTS AC OR DC

 

N.O.

COM

N.C.

N.O.

COM

N.C.

 

 

 

 

 

 

 

MAXIMUM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAGNETIC

RE-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DOOR LOCK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TELEPHONE ENTRY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SYSTEM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRIC

 

 

 

 

 

DOOR STRIKE

TRANSFORMER

 

 

 

 

ACCESS

TRANSFORMER

 

 

 

 

 

DEVICE

 

 

 

 

 

 

POWER

 

BATTERY NEGATIVE

 

 

 

 

 

 

 

 

 

 

 

SUPPLY

 

 

 

 

 

 

BATTERY POSITIVE

 

 

 

 

 

 

 

SENSE #1

 

 

 

 

 

16 VAC

 

 

 

 

 

 

 

 

OPEN #1

 

 

 

 

 

20 VA

 

SENSE #2

 

 

 

 

TRANSFORMER

 

 

 

 

 

 

 

OPEN #2

 

 

 

 

 

 

 

COMMON

 

CASE

 

TO HOUSE

RING

 

 

 

GROUND

HOUSE

 

 

 

 

 

KEYPAD CLK

 

 

 

PHONES

TIP

 

 

KEYPAD DVAL

 

 

 

 

RING

RE-1

TELEPHONE

KEYPAD DAT 0

 

 

 

 

TIP

HOUSE

 

 

 

 

 

BYPASS

KEYPAD DAT 1

 

 

 

 

RING

 

 

 

 

 

RE-1

MODULE

KEYPAD GND

 

 

 

 

TIP

TELCO

EARTH

KEYPAD PWR

 

 

 

TO TELCO

RING

 

GROUND

 

 

 

TELCO

 

 

 

 

 

 

 

 

 

 

 

LINE

TIP

 

 

 

 

EARTH

 

 

RING

TIP

TIP RING

10' MAXIMUM

 

 

 

 

 

 

 

 

 

 

HOUSE

TELCO

 

WIRE RUN

 

 

10' MAXIMUM

 

 

 

 

 

 

 

 

GROUND

GROUND

WIRE RUN

 

 

 

 

STAKE

STAKE

 

4

Page 6
Image 6