ENTRY SYSTEM MOUNTING

Pedestal Mounting

The RE-1 Entry System can be mounted on a standard pedestal.

1.Open the RE-1 case by removing the two security screws with the wrench provided (see Figure 2).

2.Use four security bolts and locking nuts to secure the backplate to the pedestal (see Figure 3).

Wall Mounting

The RE-1 Entry System can be mounted directly to a wall or fl at surface.

1.Open the RE-1 case by removing the two security screws with the wrench provided (see Figure 2).

2.Use the appropriate fasteners to secure the system’s backplate to the mounting surface. When mounting the system to a concrete wall, use concrete wedge anchors (see Figure 4).

REMOVE THE TWO

SECURITY SCREWS

TO OPEN THE CASE

Figure 2. Opening the RE-1 Case

TELEPHONE WIRING

The RE-1 connects between the incoming telephone line of the residence and local telephone sets.

Telephone Bypass Module

The RE-1’s Telephone Bypass Module provides surge protection and a switch to remove the RE-1 from the telephone line and re-connect the local telephones to the telephone system. ALL TELEPHONE

WIRING FOR THE RE-1 MUST PASS THROUGH THE BYPASS MODULE.

The bypass module is housed in a weather-resistant enclosure and should be located in an area that is easily accessible to the resident. In case of system trouble, the resident can use the bypass switch to remove the RE-1 from the telephone system.

Telephone Wiring

DO NOT ROUTE TELEPHONE AND AC WIRING INSIDE THE SAME CONDUIT. Route all telephone wires inside a dedicated conduit that is at least six inches away from any AC line wiring.

All telephone wiring must be made on the “house” side of the telephone company’s demarcation device (the terminal block where the telephone line connects to the residence).

If any security system or personal alert system at the residence is connected to the telephone line, be sure that it is connected to the line ahead of the Telephone Bypass Module using a RJ-31X or RJ-38X interface.

Use only high-quality telephone wire rated for direct underground burial. All telephone wire should be twisted-pair with a minimum size of 24 AWG.

Typical Telephone Wiring

1.

Connect the bypass module’s EARTH GROUND terminal to a good

 

earth ground.

2.

Before connecting the incoming telephone line to the bypass module

 

check the polarity of the wires with a DC voltmeter. Connect the

PEDESTAL

MOUNTING

PEDESTAL

MOUNT BACKPLATE

WITH SECURITY BOLTS

AND LOCKNUTS

CAUTION!

BE SURE THE MOUNTING HARDWARE DOES NOT EXTEND MORE THAN 1/2" INSIDE THE BACKPLATE OR ELECTRICAL DAMAGE MAY OCCUR

 

negative wire (RING - usually green) to the bypass module TELCO

 

RING terminal. Connect the positive wire (TIP - usually red) to the

 

bypass module TELCO TIP terminal.

3.

Connect the resident’s local telephone line RING (usually green) to

 

the bypass module HOUSE RING. Connect the local telephone line

 

TIP (usually red) to the bypass module HOUSE TIP terminal.

4.

Connect the RE-1 TELCO RING to the bypass module RE-1 TELCO

 

RING terminal. Connect the RE-1 TELCO TIP to the bypass module

 

RE-1 TELCO TIP terminal.

5.

Connect the RE-1 HOUSE RING to the bypass module RE-1 HOUSE

 

RING terminal. Connect the RE-1 HOUSE TIP to the bypass module

 

RE-1 HOUSE TIP terminal.

Figure 3. Pedestal Mounting Backplate

WALL

MOUNTING

USE WEDGE ANCHORS FOR CONCRETE OR OTHER APPROPRIATE ANCHORS FOR DIFFERENT MATERIALS

CASE

GROUND SCREW

CAUTION!

BE SURE THE MOUNTING HARDWARE DOES NOT EXTEND MORE THAN 1/2" INSIDE THE BACKPLATE OR ELECTRICAL DAMAGE MAY OCCUR

TELEPHONE

 

 

 

 

BYPASS

 

 

 

 

MODULE

EARTH

RE-1

 

 

ENTRY

 

 

TIP

 

 

 

TELCO

SYSTEM

 

 

RING

 

 

 

 

CASE

 

 

TIP

 

 

 

HOUSE

GROUND

 

 

RING

 

 

 

 

 

 

TO HOUSE

RING

HOUSE

 

 

PHONES

TIP

 

 

 

 

 

 

RING

RE-1

TELEPHONE

 

 

TIP

HOUSE

 

 

RING

 

BYPASS

 

 

RE-1

MODULE

 

 

TIP

TELCO

EARTH

GROUND

 

 

TO TELCO

RING

 

GROUND

STAKE

TELCO

 

 

LINE

TIP

 

 

 

 

 

Figure 4. Wall Mounting Backplate

Figure 5. Telephone Wiring

5

Page 7
Image 7
Linear RE-1 manual Entry System Mounting, Telephone Wiring