COMPONENT LOCATIONS

 

2

5

 

7

1

3

4

6

8

 

 

 

17

15

 

 

 

20

18

14

12

 

 

16

 

10

9

 

19

 

13

 

 

 

 

 

11

 

1HELP BUTTON

Pressing this button causes the system to play the help message to instruct the visitor on system use.

2CALL BUTTON

Pressing this button causes the system to call the residence telephones with a distinctive ring signal.

3OPTIONAL COLOR CCTV CAMERA

Location for the optional Model CCM-2 color CCTV camera. The camera views the keypad area.

4ANTENNA CONNECTOR

For connection to a Model EXA-1000 or EXA-2000 remote antenna.

5DIGITAL SPEECH VOLUME CONTROL

Controls the audio level of the voice synthesizer. This adjustment effects the audio level of the voice synthesizer and system tone from the speaker.

6LINE MONITOR JUMPER

For testing and troubleshooting. Remove jumper to listen to telephone line audio through the speaker.

7CAMERA CONNECTOR

Provides power and video connection for the optional Model CCM-2 CCTV camera.

8VIDEO OUT CONNECTOR

For cable connection to a video monitor. (Optional Model CCM-2 CCTV camera required).

9TELEPHONE TERMINAL BLOCK

For telephone line and earth ground connections.

10RESTART BUTTON

Pressing this button restarts the system. This button DOES NOT erase any programming data.

11MAIN TERMINAL BLOCK

For power, backup battery, sense inputs, open request inputs, and remote keypad connections.

12STATUS INDICATORS

Six indicators light to display system power, radio, and modem status.

13SPEAKERPHONE VOLUME CONTROL

Controls the audio level produced by the speaker during communications between the visitor and the resident.

14RELAY TERMINAL BLOCK

For Relay #1 and Relay #2 output connections to the access control devices.

15RELAY INDICATORS

Indicators for Relay #1 and Relay #2 will light when the relay is activated.

16SPEAKER

Weatherproof speaker for system operation and programming.

17DOWNLIGHT

Illuminates keypad and visitor operation buttons. The light operates dusk to dawn and adjusts its time depending on the system’s geographic location.

18KEYPAD

Die-cast metal 12-key keypad with tactile action. For system programming and keying in entry codes.

19OPTIONAL KEYLOCK

Location for mounting access keylock.

20MICROPHONE

The high-sensitivity microphone monitors sound at the keypad area for the entry system’s speakerphone.