Indicator Descriptions
INDICATOR DEFINITION
OPERATION | PROGRAMMING |
INDICATION WHEN LIT
DURING NORMAL OPERATION
INDICATION WHEN LIT
DURING PROGRAMMING
24 VOLT INPUT |
| LOW VOLTAGE AC POWER IS PRESENT |
| |
POWER |
|
| ||
|
|
| ||
|
|
|
| |
24 VOLT DC |
| LOW VOLTAGE DC POWER IS PRESENT |
| |
ACCY POWER |
|
| ||
|
|
| ||
|
|
|
| |
|
| OPEN SIGNAL PRESENT FROM THE INTERNAL |
| |
OPEN |
| RECEIVER OR AN EXTERNAL DEVICE |
| |
|
| CONNECTED TO THE OPEN INPUT TERMINAL |
| |
|
|
|
| |
CLOSE |
| CLOSE SIGNAL IS PRESENT FROM A DEVICE |
| |
| CONNECTED TO THE CLOSE INPUT TERMINAL |
| ||
|
|
| ||
|
|
|
| |
STOP |
| STOP INPUT TERMINAL IS OPEN AND |
| |
| NOT CONNECTED TO COMMON |
| ||
|
|
| ||
|
|
|
| |
PROGRAM |
|
| CONTROLLER IS IN PROGRAMMING MODE | |
|
|
|
| |
REVERSE | DELAY SET | SIGNAL FROM REVERSING DEVICE IS PRESENT | SET REVERSE DELAY TIME | |
|
|
|
| |
LOCKOUT | ALARM SET | CONTROLS AND OPERATOR ARE LOCKED OUT | SET RUN ALARM AND | |
BECAUSE OF EXISTING TROUBLE CONDITION | ||||
|
|
| ||
|
|
|
| |
RADIO | LEARN | TRANSMITTERS CAN BE ENTERED INTO | ||
SIGNAL FROM A REMOTE CONTROL | MEMORY (UP TO 40 TRANSMITTERS) | |||
|
| |||
|
|
|
| |
OPEN CURRENT | SET | MOTOR CURRENT HAS EXCEEDED THE | SET MAXIMUM OPEN CURRENT | |
OPEN CURRENT SETTING WHILE OPENING | ||||
|
|
| ||
|
|
|
| |
|
| OPEN OBSTRUCTION TERMINAL CONNECTED |
| |
OPEN OBSTR | MGT 2 SET | TO COMMON BY BEAM OR SAFETY EDGE, OR | SET MGT #2 FUNCTION | |
|
| SIGNAL FROM MGT OBSTACLE TRANSMITTER |
| |
|
|
|
| |
OPEN RELAY | LH/RH SET | OPEN RELAY IS ACTIVATED | SET | |
|
|
|
| |
OPEN LIMIT | BRAKE DELAY | OPEN LIMIT SWITCH IS ACTIVATED |
| |
|
|
|
| |
CLOSE CURRENT | SET | MOTOR CURRENT HAS EXCEEDED THE | SET MAXIMUM CLOSE CURRENT | |
CLOSE CURRENT SETTING WHILE CLOSING | ||||
|
|
| ||
|
|
|
| |
|
| CLOSE OBSTRUCTION TERMINAL CONNECTED |
| |
CLOSE OBSTR | MGT 1 SET | TO COMMON BY BEAM OR SAFETY EDGE, OR | SET MGT #1 FUNCTION | |
|
| SIGNAL FROM MGT OBSTACLE TRANSMITTER |
| |
|
|
|
| |
CLOSE RELAY | AUTO CLOSE SET | CLOSE RELAY IS ACTIVATED | SET | |
|
|
|
| |
CLOSE LIMIT | AC DC SET | CLOSE LIMIT SWITCH IS ACTIVATED | SET MOTOR TYPE | |
|
|
|
| |
SINGLE | SET | SINGLE TERMINAL CONNECTED TO COMMON | SET SINGLE BUTTON INPUT FUNCTION | |
BY AN EXTERNAL PUSHBUTTON OR RADIO | ||||
|
|
| ||
|
|
|
| |
MAX RUN | SET | MAXIMUM RUN TIMER HAS BEEN EXCEEDED | SET MAXIMUM RUN TIME | |
|
|
|
| |
COMM LINK | SET | DUAL OPERATOR CONNECTION DETECTED, |
| |
BLINKS IF CONNECTION HAS FAILED |
| |||
|
|
| ||
|
|
|
| |
MAINT ALERT | SET | MAINTENANCE IS REQUIRED ON OPERATOR | SET MAINTENANCE ALERT CYCLE COUNT | |
|
|
|
|
"RL"
LEFT OR RIGHT HAND OPERATION
APEX FUNCTION DISPLAY INDICATIONS
MOTOR TYPE
"MO" SELECTION
"PM"
SINGLE OR DUAL GATE
![]()
![]()
![]()
![]()
![]()
"RT"
MAXIMUM RUN TIMER
LOW POWER
"LP" MODE
![]()
![]()
![]()
![]()
![]()
![]()
"RA"
RADIO ENABLE
![]()
![]()
![]()
![]()
![]()
![]()
"AC"
![]()
![]()
![]()
![]()
![]()
![]()
"RP"
"OC"
"CC"
![]()
![]()
![]()
![]()
![]()
![]()
"AD"
AUTO CLOSE
TIMER
RUN ALARM
MAXIMUM OPEN CURRENT
MAXIMUM CLOSE CURRENT
ADVANCED PROGRAMMING
![]()
![]()
![]()
![]()
![]()
"SB"
"SM"
![]()
![]()
![]()
![]()
![]()
"ST"
![]()
![]()
![]()
![]()
![]()
![]()
"AR"
![]()
![]()
![]()
![]()
![]()
"RD"
SINGLE BUTTON INPUT SETUP
STAGGER
MODE
STAGGER
TIME
AUXILIARY RELAY MODE
REVERSE
DELAY TIME
![]()
![]()
![]()
![]()
![]()
"FS"
![]()
![]()
![]()
![]()
![]()
"SS"
![]()
![]()
![]()
"CT"
![]()
![]()
![]()
![]()
"MA"
![]()
![]()
![]()
"MT"
POWER
FAILURE MODE
SOFT START/STOP DURATION
RESET CYCLE
COUNT
MAINTENANCE ALERT TRIGGER
STOP POSITION
"TL"
![]()
![]()
![]()
![]()
![]()
"TD"
"ML"
![]()
![]()
![]()
"MD"
"CL"
LEARN TRANSMITTERS
DELETE TRANSMITTERS
LEARN MGT TRANSMITTERS
ERASE MGT TRANSMITTERS
RESET TO FACTORY DEFAULTS
SLR • SLC • SLD Slide Gate Operator Installation Guide | - 8 - | 227968 Revision X13 |