Linear SLC, SLD, SLR manual Terminal Descriptions, Terminal Group Function

Models: SLD SLR SLC

1 36
Download 36 pages 21.87 Kb
Page 11
Image 11

Terminal Descriptions

TERMINAL

GROUP

FUNCTION

AC N

24 VOLT INPUT

FACTORY CONNECTED TO 24 VAC FROM TRANSFORMER OR

AC

24 VDC FROM CONTINUOUS DUTY DC SUPPLY.

 

DC -

ACCESSORY POWER

PROVIDES 24 VOLT DC POWER FOR ACCESSORIES. (.5A MAX)

 

DC +

 

 

RESET

RESET BUTTON

FACTORY CONNECTED TO THE CONTROLLER’S RESET BUTTON.

 

COMMON

 

 

C

 

 

 

 

 

B

COMM LINK

FOR 3-WIRE NETWORK CONNECTION TO SECOND OPERATOR IN DUAL GATE INSTALLATIONS.

 

 

 

A

 

 

 

 

 

COMMON

SINGLE BUTTON INPUT

CONNECT TO NORMALLY OPEN SWITCH FOR SINGLE BUTTON OPERATION. ALTERNATES

SINGLE

BETWEEN OPEN-CLOSE OR OPEN-STOP-CLOSE DEPENDING ON PROGRAMMING.

 

 

 

 

COMMON

FIRE BOX INPUT

CONNECT TO NORMALLY OPEN SWITCH IN FIRE BOX FOR FIRE DEPARTMENT ACCESS.

 

FIRE DEPT

 

 

 

 

 

COMMON

 

CONNECT TO NORMALLY OPEN DEVICES (KEYPAD, CARD READER, KEYSWITCH,

 

OPEN INPUT

TELEPHONE ENTRY SYSTEM) TO OPEN THE GATE. A CONSTANT OPEN INPUT WILL

OPEN

 

OVERRIDE THE MID-TRAVEL STOP AND HALT THE AUTO CLOSE TIMER UNTIL RELEASED.

 

 

OPEN

 

 

 

 

 

CLOSE

3-BUTTON

CONNECT TO 3-BUTTON STATION FOR OPEN-CLOSE-STOP CONTROL. A CONSTANT OPEN INPUT

COMMON

STATION INPUT

WILL OVERRIDE THE MID-TRAVEL STOP AND HALT THE AUTO CLOSE TIMER UNTIL RELEASED.

 

 

 

STOP

 

 

COM

 

CONNECT TO NORMALLY OPEN DEVICES (GATE EDGE, PHOTO BEAM) TO DETECT AN

 

 

OBSTRUCTION DURING OPENING. WHILE GATE IS IN MOTION, ANY OPEN OBSTRUCTION

O-OBS

 

 

SIGNAL WILL CAUSE THE GATE TO STOP, REVERSE A SHORT DISTANCE, AND THEN

 

 

 

 

STOP AGAIN. AT THIS TIME THE AUTO CLOSE TIMER IS DISABLED, AND A RENEWED

 

OBSTRUCTION INPUTS

INPUT WILL BE REQUIRED TO START THE GATE AGAIN. SHOULD THE GATE BE

 

RESTARTED AND THE OBSTACLE SIGNAL OCCUR AGAIN PRIOR TO REACHING A LIMIT,

 

 

 

 

THE GATE WILL STOP AGAIN, LOCKOUT, AND SOUND THE EMERGENCY ALARM.

 

 

 

C-OBS

 

FUNCTIONS THE SAME AS THE OPEN OBSTRUCTION, EXCEPT IN THE CLOSING DIRECTION.

 

 

COM

 

 

 

 

 

 

COM

REVERSE

CONNECT TO NORMALLY OPEN DEVICES TO CAUSE A REVERSAL WHEN THE GATE IS

REV

TRAVELING CLOSED. THE GATE WILL REVERSE TO THE FULL OPEN POSITION.

 

 

 

 

OPEN LOOP

 

CONNECT TO OPEN LOOP/FREE EXIT LOOP. THE GATE WILL OPEN

 

OPEN LOOP

WHEN THE LOOP IS TRIGGERED, AND REMAIN OPEN AS LONG AS

OPEN LOOP

 

THE LOOP IS TRIGGERED. REQUIRES LOOP DETECTOR.

 

 

REVERSE LOOP

 

CONNECT TO REVERSE LOOP. TRIGGERING THE LOOP WILL CAUSE A

 

REVERSE LOOP

REVERSAL WHEN THE GATE IS TRAVELING CLOSED. THE GATE WILL REVERSE

REVERSE LOOP

 

TO THE FULL OPEN POSITION. REQUIRES LOOP DETECTOR.

 

 

SHADOW/RESET LOOP

 

CONNECT TO SHADOW/RESET LOOP TO KEEP THE GATE IN ITS FULLY OPEN

 

SHADOW/RESET LOOP

POSITION AS LONG AS THE SIGNAL IS PRESENT. USED TO KEEP GATE OPEN

SHADOW/RESET LOOP

 

WHILE VEHICLE IS PASSING THROUGH. REQUIRES LOOP DETECTOR.

 

 

-

ALARM

FACTORY CONNECTED TO THE ALARM BEEPER.

 

+

 

 

N.O.

 

FOR CONNECTION TO AUXILIARY DEVICES (MAGNETIC LOCK, SOLENOID LOCK,

 

 

COM

AUX RELAY

STROBE LIGHT) FOR ACTIVATION (OR DEACTIVATION) DURING GATE OPERATION.

 

 

N.C.

 

 

 

 

 

 

+

24 VOLT SOLAR PANEL

FOR CONNECTION TO 24 VOLT SOLAR PANEL FOR BATTERY CHARGING.

 

-

 

 

 

 

 

+

24 VOLT BATTERY

FACTORY CONNECTED TO BATTERIES IN DC MODEL OPERATORS.

 

-

 

 

 

 

 

SLR SLC SLD  Slide Gate Operator Installation Guide

- 9 -

227968 Revision X13 2-3-09

Page 11
Image 11
Linear SLC, SLD, SLR manual Terminal Descriptions, Terminal Group Function