Terminal Descriptions
TERMINAL
GROUP
FUNCTION
| AC N | 24 VOLT INPUT | FACTORY CONNECTED TO 24 VAC FROM TRANSFORMER OR | |
| AC | 24 VDC FROM CONTINUOUS DUTY DC SUPPLY. | ||
| 
 | |||
| DC - | ACCESSORY POWER | PROVIDES 24 VOLT DC POWER FOR ACCESSORIES. (.5A MAX) | |
| 
 | |||
| DC + | |||
| 
 | 
 | ||
| RESET | RESET BUTTON | FACTORY CONNECTED TO THE CONTROLLER’S RESET BUTTON. | |
| 
 | |||
| COMMON | |||
| 
 | 
 | ||
| C | 
 | 
 | |
| 
 | 
 | 
 | |
| B | COMM LINK | FOR  | |
| 
 | 
 | 
 | |
| A | 
 | 
 | |
| 
 | 
 | 
 | |
| COMMON | SINGLE BUTTON INPUT | CONNECT TO NORMALLY OPEN SWITCH FOR SINGLE BUTTON OPERATION. ALTERNATES | |
| SINGLE | BETWEEN  | ||
| 
 | |||
| 
 | 
 | 
 | |
| COMMON | FIRE BOX INPUT | CONNECT TO NORMALLY OPEN SWITCH IN FIRE BOX FOR FIRE DEPARTMENT ACCESS. | |
| 
 | |||
| FIRE DEPT | |||
| 
 | 
 | ||
| 
 | 
 | 
 | |
| COMMON | 
 | CONNECT TO NORMALLY OPEN DEVICES (KEYPAD, CARD READER, KEYSWITCH, | |
| 
 | OPEN INPUT | TELEPHONE ENTRY SYSTEM) TO OPEN THE GATE. A CONSTANT OPEN INPUT WILL | |
| OPEN | |||
| 
 | OVERRIDE THE  | ||
| 
 | 
 | ||
| OPEN | 
 | 
 | |
| 
 | 
 | 
 | |
| CLOSE | CONNECT TO  | ||
| COMMON | STATION INPUT | WILL OVERRIDE THE  | |
| 
 | 
 | 
 | |
| STOP | 
 | 
 | |
| COM | 
 | CONNECT TO NORMALLY OPEN DEVICES (GATE EDGE, PHOTO BEAM) TO DETECT AN | |
| 
 | 
 | OBSTRUCTION DURING OPENING. WHILE GATE IS IN MOTION, ANY OPEN OBSTRUCTION | |
| 
 | 
 | ||
| 
 | SIGNAL WILL CAUSE THE GATE TO STOP, REVERSE A SHORT DISTANCE, AND THEN | ||
| 
 | 
 | ||
| 
 | 
 | STOP AGAIN. AT THIS TIME THE AUTO CLOSE TIMER IS DISABLED, AND A RENEWED | |
| 
 | OBSTRUCTION INPUTS | INPUT WILL BE REQUIRED TO START THE GATE AGAIN. SHOULD THE GATE BE | |
| 
 | RESTARTED AND THE OBSTACLE SIGNAL OCCUR AGAIN PRIOR TO REACHING A LIMIT, | ||
| 
 | 
 | ||
| 
 | 
 | THE GATE WILL STOP AGAIN, LOCKOUT, AND SOUND THE EMERGENCY ALARM. | |
| 
 | 
 | 
 | |
| 
 | FUNCTIONS THE SAME AS THE OPEN OBSTRUCTION, EXCEPT IN THE CLOSING DIRECTION. | ||
| 
 | 
 | ||
| COM | 
 | ||
| 
 | 
 | ||
| 
 | 
 | 
 | |
| COM | REVERSE | CONNECT TO NORMALLY OPEN DEVICES TO CAUSE A REVERSAL WHEN THE GATE IS | |
| REV | TRAVELING CLOSED. THE GATE WILL REVERSE TO THE FULL OPEN POSITION. | ||
| 
 | |||
| 
 | 
 | 
 | |
| OPEN LOOP | 
 | CONNECT TO OPEN LOOP/FREE EXIT LOOP. THE GATE WILL OPEN | |
| 
 | OPEN LOOP | WHEN THE LOOP IS TRIGGERED, AND REMAIN OPEN AS LONG AS | |
| OPEN LOOP | |||
| 
 | THE LOOP IS TRIGGERED. REQUIRES LOOP DETECTOR. | ||
| 
 | 
 | ||
| REVERSE LOOP | 
 | CONNECT TO REVERSE LOOP. TRIGGERING THE LOOP WILL CAUSE A | |
| 
 | REVERSE LOOP | REVERSAL WHEN THE GATE IS TRAVELING CLOSED. THE GATE WILL REVERSE | |
| REVERSE LOOP | |||
| 
 | TO THE FULL OPEN POSITION. REQUIRES LOOP DETECTOR. | ||
| 
 | 
 | ||
| SHADOW/RESET LOOP | 
 | CONNECT TO SHADOW/RESET LOOP TO KEEP THE GATE IN ITS FULLY OPEN | |
| 
 | SHADOW/RESET LOOP | POSITION AS LONG AS THE SIGNAL IS PRESENT. USED TO KEEP GATE OPEN | |
| SHADOW/RESET LOOP | |||
| 
 | WHILE VEHICLE IS PASSING THROUGH. REQUIRES LOOP DETECTOR. | ||
| 
 | 
 | ||
| - | ALARM | FACTORY CONNECTED TO THE ALARM BEEPER. | |
| 
 | |||
| + | |||
| 
 | 
 | ||
| N.O. | 
 | FOR CONNECTION TO AUXILIARY DEVICES (MAGNETIC LOCK, SOLENOID LOCK, | |
| 
 | 
 | ||
| COM | AUX RELAY | ||
| STROBE LIGHT) FOR ACTIVATION (OR DEACTIVATION) DURING GATE OPERATION. | |||
| 
 | 
 | ||
| N.C. | 
 | ||
| 
 | 
 | ||
| 
 | 
 | 
 | |
| + | 24 VOLT SOLAR PANEL | FOR CONNECTION TO 24 VOLT SOLAR PANEL FOR BATTERY CHARGING. | |
| 
 | |||
| - | |||
| 
 | 
 | ||
| 
 | 
 | 
 | |
| + | 24 VOLT BATTERY | FACTORY CONNECTED TO BATTERIES IN DC MODEL OPERATORS. | |
| 
 | |||
| - | |||
| 
 | 
 | ||
| 
 | 
 | 
 | 