Terminal Descriptions
TERMINAL
GROUP
FUNCTION
AC N | 24 VOLT INPUT | FACTORY CONNECTED TO 24 VAC FROM TRANSFORMER OR | |
AC | 24 VDC FROM CONTINUOUS DUTY DC SUPPLY. | ||
| |||
DC - | ACCESSORY POWER | PROVIDES 24 VOLT DC POWER FOR ACCESSORIES. (.5A MAX) | |
| |||
DC + | |||
|
| ||
RESET | RESET BUTTON | FACTORY CONNECTED TO THE CONTROLLER’S RESET BUTTON. | |
| |||
COMMON | |||
|
| ||
C |
|
| |
|
|
| |
B | COMM LINK | FOR | |
|
|
| |
A |
|
| |
|
|
| |
COMMON | SINGLE BUTTON INPUT | CONNECT TO NORMALLY OPEN SWITCH FOR SINGLE BUTTON OPERATION. ALTERNATES | |
SINGLE | BETWEEN | ||
| |||
|
|
| |
COMMON | FIRE BOX INPUT | CONNECT TO NORMALLY OPEN SWITCH IN FIRE BOX FOR FIRE DEPARTMENT ACCESS. | |
| |||
FIRE DEPT | |||
|
| ||
|
|
| |
COMMON |
| CONNECT TO NORMALLY OPEN DEVICES (KEYPAD, CARD READER, KEYSWITCH, | |
| OPEN INPUT | TELEPHONE ENTRY SYSTEM) TO OPEN THE GATE. A CONSTANT OPEN INPUT WILL | |
OPEN | |||
| OVERRIDE THE | ||
|
| ||
OPEN |
|
| |
|
|
| |
CLOSE | CONNECT TO | ||
COMMON | STATION INPUT | WILL OVERRIDE THE | |
|
|
| |
STOP |
|
| |
COM |
| CONNECT TO NORMALLY OPEN DEVICES (GATE EDGE, PHOTO BEAM) TO DETECT AN | |
|
| OBSTRUCTION DURING OPENING. WHILE GATE IS IN MOTION, ANY OPEN OBSTRUCTION | |
|
| ||
| SIGNAL WILL CAUSE THE GATE TO STOP, REVERSE A SHORT DISTANCE, AND THEN | ||
|
| ||
|
| STOP AGAIN. AT THIS TIME THE AUTO CLOSE TIMER IS DISABLED, AND A RENEWED | |
| OBSTRUCTION INPUTS | INPUT WILL BE REQUIRED TO START THE GATE AGAIN. SHOULD THE GATE BE | |
| RESTARTED AND THE OBSTACLE SIGNAL OCCUR AGAIN PRIOR TO REACHING A LIMIT, | ||
|
| ||
|
| THE GATE WILL STOP AGAIN, LOCKOUT, AND SOUND THE EMERGENCY ALARM. | |
|
|
| |
| FUNCTIONS THE SAME AS THE OPEN OBSTRUCTION, EXCEPT IN THE CLOSING DIRECTION. | ||
|
| ||
COM |
| ||
|
| ||
|
|
| |
COM | REVERSE | CONNECT TO NORMALLY OPEN DEVICES TO CAUSE A REVERSAL WHEN THE GATE IS | |
REV | TRAVELING CLOSED. THE GATE WILL REVERSE TO THE FULL OPEN POSITION. | ||
| |||
|
|
| |
OPEN LOOP |
| CONNECT TO OPEN LOOP/FREE EXIT LOOP. THE GATE WILL OPEN | |
| OPEN LOOP | WHEN THE LOOP IS TRIGGERED, AND REMAIN OPEN AS LONG AS | |
OPEN LOOP | |||
| THE LOOP IS TRIGGERED. REQUIRES LOOP DETECTOR. | ||
|
| ||
REVERSE LOOP |
| CONNECT TO REVERSE LOOP. TRIGGERING THE LOOP WILL CAUSE A | |
| REVERSE LOOP | REVERSAL WHEN THE GATE IS TRAVELING CLOSED. THE GATE WILL REVERSE | |
REVERSE LOOP | |||
| TO THE FULL OPEN POSITION. REQUIRES LOOP DETECTOR. | ||
|
| ||
SHADOW/RESET LOOP |
| CONNECT TO SHADOW/RESET LOOP TO KEEP THE GATE IN ITS FULLY OPEN | |
| SHADOW/RESET LOOP | POSITION AS LONG AS THE SIGNAL IS PRESENT. USED TO KEEP GATE OPEN | |
SHADOW/RESET LOOP | |||
| WHILE VEHICLE IS PASSING THROUGH. REQUIRES LOOP DETECTOR. | ||
|
| ||
- | ALARM | FACTORY CONNECTED TO THE ALARM BEEPER. | |
| |||
+ | |||
|
| ||
N.O. |
| FOR CONNECTION TO AUXILIARY DEVICES (MAGNETIC LOCK, SOLENOID LOCK, | |
|
| ||
COM | AUX RELAY | ||
STROBE LIGHT) FOR ACTIVATION (OR DEACTIVATION) DURING GATE OPERATION. | |||
|
| ||
N.C. |
| ||
|
| ||
|
|
| |
+ | 24 VOLT SOLAR PANEL | FOR CONNECTION TO 24 VOLT SOLAR PANEL FOR BATTERY CHARGING. | |
| |||
- | |||
|
| ||
|
|
| |
+ | 24 VOLT BATTERY | FACTORY CONNECTED TO BATTERIES IN DC MODEL OPERATORS. | |
| |||
- | |||
|
| ||
|
|
|
SLR • SLC • SLD Slide Gate Operator Installation Guide | - 9 - | 227968 Revision X13 |