Linksys SRW2016 manual Maintenance Tab - HTTP File Download, 85 Maintenance - HTTP File Download

Models: SRW2016 SRW224G4 SRW2048 SRW248G4

1 123
Download 123 pages 42.48 Kb
Page 95
Image 95
Maintenance Tab - HTTP File Download

WebView Switches

For results on a single port, click the Edit button for that port. A new screen will appear. After clicking the Test

Now button, the following columns will be updated:

Test Result. This is the test result. OK indicates that the cable passed the test. No Cable means there is no cable connected to the port. Open Cable means the cable is connected on only one side. Short Cable indicates that a short has occurred in the cable. Undefined indicates that the test could not be properly performed.

Cable Fault Distance. This is the distance from the port at which the cable error occurred.

Figure 5-84: Integrated Cable Test - Perform Test

Last Update. This is the last time the port was tested.

Approximate Cable Length. This is the approximate length of the tested cable. The Approximate Cable Length test can be performed only when the port is up and operating at 1Gbps.

Maintenance Tab - HTTP File Download

The HTTP File Download screen allows you to download a file to the Switch via HTTP.

Source File Name. Enter the file path of the file you want to download, or click the Browse button to browse for the source file.

Click the Submit button to begin the download.

Figure 5-85: Maintenance - HTTP File Download

 

Chapter 5: Using the Web-based Utility for Configuration

85

Maintenance Tab - HTTP File Download

Page 95
Image 95
Linksys SRW2016, SRW248G4, SRW2048, SRW224G4 manual Maintenance Tab - HTTP File Download, 85 Maintenance - HTTP File Download