3Gas connections

Installation & Service Manual

3Gas connections

Gas Supply

Gas Pressure Test

Verify that the appliance is supplied with the type gas specified on the rating plate. This appliance is orificed for operation up to 2000 feet altitude. The appliance will be derated 4% per 1000 feet above 2000 feet elevation. Consult the factory for installations above 2000 feet elevation. Field conversions for operation at high altitude must be performed by certified personnel only. The appliance will be marked to indicate suitability for high altitude operation.

GAS SUPPLY PRESSURE: Measured at the inlet pressure tap located upstream of the combination gas valve(s) see FIG. 3-5, page 22.

TABLE - 3A

GAS SUPPLY PRESSURE

 

Natural Gas

LP Gas

Max. (Inches Water Column)

 

 

14

14

 

 

 

Min. (Inches Water Column)

4.5

11

 

 

 

Maximum inlet gas pressure must not exceed the value specified. Minimum value listed is for the purposes of input adjustment.

MANIFOLD PRESSURE: Measured at the pressure tap on the downstream side of the combination gas valve(s) (see FIG. 3-5, page 22). The gas regulator settings for single stage and two stage operation are factory set to supply proper manifold pressure for normal operation. To check manifold pressure, see Manifold Adjustment Procedure. Do not increase manifold pressure beyond specified pressure settings shown below in Table 3B.

 

TABLE - 3B

 

 

MANIFOLD PRESSURE

 

 

 

 

 

 

 

Single and

Two Stage

 

Two-Stage

 

 

 

Input Gas

 

 

 

 

Full or High Fire

Low Fire Settings

Btu/hr

Settings

 

 

 

Natural

LP Gas

Natural

LP Gas

 

Gas

 

Gas

 

45,000

3.5"

10"

0.9"

2.5"

 

 

 

 

 

75,000

2.4"

7"

0.9"

2.5"

 

 

 

 

 

90,000 - 180,000

3.5"

10"

0.9"

2.5"

 

 

 

 

 

215,000 - 260,000

3.5"

10"

0.9"

2.5"

 

 

 

 

 

Gas Supply 18 Gas Pressure Test

1.The appliance must be disconnected from the gas supply piping system during any pressure testing of that system at a test pressure in excess of 1/2 PSIG (3.5kPa).

2.The appliance must be isolated from the gas supply piping system by closing a manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 PSIG (3.5kPa).

3.The appliance and its gas connection must be leak-tested before placing it in operation.

Gas Connection

1.Safe operation of the appliance requires properly sized gas supply piping. See data in Table 3C.

2.Gas pipe size may be larger than appliance gas connection.

3.Installation of a union is suggested for ease of service, see FIG. 3-1 on page 19.

4.Install a manual main gas shutoff valve, outside of the appliance gas connection and before the gas valve or manifold connection, when local codes require.

5.A trap (drip leg) MUST be provided by the installer in the inlet of the gas connection to the appliance, see FIG. 3-1 on page 19.

6.The combination gas valve has an integral vent limiting device and does not require venting to atmosphere, outside the building.

7.Optional gas controls may require routing of bleeds and vents to the atmosphere, outside the building when required by local codes.

TABLE - 3C

FITTINGS TO EQUIVALENT STRAIGHT PIPE

Diameter Pipe (inches)

3/4

1

1 1/4

1 1/2

2

3

4

5

 

 

 

 

 

 

 

 

 

Equivalent Length of Straight Pipe (feet)

 

 

 

 

 

 

 

 

 

2

2

3

4

5

10

14

20

 

 

 

 

 

 

 

 

TABLE - 3D

GAS CONNECTIONS

Btu/hr

Pipe Size

INPUT

 

 

 

45,000 - 135,000

1/2"

 

 

180,000 - 260,000

3/4"

 

 

Page 18