Sight Glass Location

 

 

TNR-I&S-02

TEMPERATURE ADJUSTMENT

Figure 25

Sight Glass Location

The temperature selector knob of the thermostat has been adjusted to

 

 

120° F when shipped from the factory.

 

 

NOTICE

 

 

The lower the temperature setting, the greater the energy efficiency,

 

 

both to heat the water and to maintain the storage temperature

 

 

during standby periods. Lower water temperatures also extend tank

 

 

life. Remember, no water heating system will provide exact

 

 

temperatures at all times. Allow a few days of operation at this

 

 

setting to determine the correct temperature setting consistent with

 

 

the requirements for the installation.

 

 

CAUTION

 

 

This water heater, when set at a lower temperature setting is not

 

 

capable of producing hot water of sufficient temperature for sanitizing

 

 

purposes.

 

 

During the winter season or any cold period, you may desire a higher

 

 

temperature setting to adjust for the colder incoming water. This adjustment,

 

 

however, may cause additional condensation to form on the colder tank

 

 

surface. This does not mean the tank is leaking. During summer months,

 

MAINTENANCE

the warmer incoming water temperatures will benefit the performance of

 

 

 

your water heater and reduce the amount of condensation developed.

 

DANGER

 

 

Condensation does not mean your tank is leaking. Most of reported tank

DO NOT ATTEMPT TO REPAIR GAS VALVE.

DO NOT ATTEMPT TO REPAIR IGNITION MODULE.

leaks on installation are proven to be condensation. To avoid unnecessary

DO NOT ATTEMPT TO REPAIR VENTURI.

inconvenience and expense, make sure the tank is leaking before calling

DO NOT ATTEMPT TO REPAIR THERMOSTAT BOARD.

an independent servicing contractor or qualified service professional.

DO NOT ATTEMPT TO REPAIR TRANSFORMER.

 

 

 

 

 

 

 

 

 

 

DO NOT ATTEMPT TO REPAIR PRESSURE SWITCH.

 

 

 

DANGER

 

 

 

 

 

 

 

 

 

 

Hotter water increases the risk of scald injury. Scalding may occur

 

 

within 5 seconds at a temperature setting of 135°F (57°C). To protect

 

GENERAL

against hot water injury, install an anti-scald tempering valve in the

 

water system. This valve will reduce point of discharge temperature

 

 

by mixing cold and hot water in branch water lines. A licensed

 

KEEP APPLIANCE AREA CLEAR AND FREE FROM COMBUSTIBLE MATERIALS,

plumbing professional or local plumbing authority should be consulted.

 

GASOLINE AND OTHER FLAMMABLE VAPORS AND LIQUIDS.

This water heater is equipped with an energy cut out device to

 

 

prevent overheating. Should overheating occur or the gas supply

 

Water heater maintenance includes periodic tank flushing and cleaning,

fail to shut off, turn off the manual gas control valve to the appliance

 

and removal of lime scale. The unit should be inspected and adjusted to

and call a qualified service agency.

 

maintain proper combustion. Refer to Table 4, “Suggested Maintenance

If the water heater is to remain idle for 30 days or more or is subjected to

Schedule”. A periodic inspection of the venting system should be made.

 

freezing temperatures while shut off, the water heater and piping should

MAINTENANCE SCHEDULE

be fully drained and the drain valve should be left fully open. Refer to the

Following are the instructions for performing some of the recommended

“General Operation” section of this Installation and Operating Instructions

maintenance. Unit inspection and adjustment should be performed by a

Manual for the procedure on draining the water heater.

competent technician.

 

 

 

 

 

BURNER FLAME CHECK

At the time of installation and at monthly intervals, a visual check of the burner flames should be made to determine if they are burning properly. The main burner may be seen through the sight glass window on the front of the combustion insert mounting bracket (Figure 25). The burner flames should be a blue flame near the burner surface in a uniform flame pattern. Occasional yellow or white streaks are normal.