M&S Systems manual Door Stations, dmc1 Master Installation

Models: dmc1

1 16
Download 16 pages 25.21 Kb
Page 8
Image 8
Door Stations
dmc1
Figure 6 - Door station connections
Figure 7 - Connector wiring diagram

Door Stations

At each door station location, strip approximately 4 inches of jacket from wire and separate colored conductors from one another. Strip ½ inch of insulation from conductors as shown in figure 1. Cut each shield drain wire at jacket to prevent them from touching each other (MS4DCXSC only). Terminate yellow and orange wires to the screw terminals on the bell button (if equipped). Connect the red and black wires to the red ban black wires on the speaker respectively. Refer to figure 6. Mount door station to housing using the two screws provided with the door station.

dmc1 Master Installation

Gather all room station and door station cables and cut cable ends to the same length approximately 12 inches from entry point into wall housing. Make sure that all cables remain properly labeled. Strip approximately 2” of insulation from each of

the CAT5 cables. Untwist the individual wire pairs. Insert each wire pair into the correct

connector location and close connector (see figure 7). Insert each cable connector into its proper location on the dmc1 master. Note: Verify that the outdoor patio speaker is connected into the Patios station cables location only. If you are connecting two patio speakers, use the screw terminal connectors provided with the dmc1RW for the patio. Connect both patio stations cables into one screw terminal connector.