With Iron Wire:

1.Using desoldering braid, remove the solder from all pins of the flat pack-IC. When you use solder flux which is applied to all pins of the flat pack-IC, you can remove it easily. (Fig. S-1-3)

2.Affix the wire to a workbench or solid mounting point, as shown in Fig. S-1-5.

3.While heating the pins using a fine tip soldering iron or hot air blower, pull up the wire as the solder melts so as to lift the IC leads from the CBA contact pads as shown in Fig. S-1-5.

4.Bottom of the flat pack-IC is fixed with glue to the CBA; when removing entire flat pack-IC, first apply soldering iron to center of the flat pack-IC and heat up. Then remove (glue will be melted). (Fig. S-1-6)

5.Release the flat pack-IC from the CBA using tweezers. (Fig. S-1-6)

Note: When using a soldering iron, care must be taken to ensure that the flat pack-IC is not being held by glue. When the flat pack-IC is removed from the CBA, handle it gently because it may be damaged if force is applied.

Hot Air Blower

or

Iron Wire

Soldering Iron

To Solid

Mounting Point

Fig. S-1-5

CBA

Fine Tip

Soldering Iron

 

Flat Pack-IC

Tweezers

 

 

Fig. S-1-6

2. Installation

1.Using desoldering braid, remove the solder from the foil of each pin of the flat pack-IC on the CBA so you can install a replacement flat pack-IC more easily.

2.The “” mark on the flat pack-IC indicates pin 1. (See Fig. S-1-7.) Be sure this mark matches the 1 on the PCB when positioning for installation. Then presolder the four corners of the flat pack-IC. (See Fig. S-1-8.)

3.Solder all pins of the flat pack-IC. Be sure that none of the pins have solder bridges.

Example :

Pin 1 of the Flat Pack-IC

 

is indicated by a " " mark.

Fig. S-1-7

 

Presolder

Flat Pack-IC

CBA

Fig. S-1-8

1-4-3

TVDVDN_SN

Page 13
Image 13
Magnavox MWC24T5 service manual Installation, With Iron Wire, Pin 1 of the Flat Pack-IC Is indicated by a mark, Presolder