P 16/16

Wiring diagram

Fig. D-4

HS6101 & HS7101

(with Electric brake and LED light)

Be careful not to put Lead wire (blue or white) of Power supply cord on Noise suppressor after connecting

it to Terminal block.

Route Field lead wires and

Fix Lead wires of

Lead wires of LED Light circuit

LED Light circuit

into Handle section through

in this Lead wire

this groove.

holder.

Switch

 

Field lead wires must be tight in Motor housing.

Fix Lead wires of LED Light circuit in these Lead wire holders.

Be careful not to put

 

 

Field

Lead wires on the boss

 

 

and ribs A, B, C, D.

 

 

 

 

 

rib C rib D

LED Light

 

 

circuit

Strain relief

 

 

 

rib A

 

 

 

Noise suppressor

rib B

 

(if used)

 

boss

Fix Field lead wires

 

 

in these Lead wire

 

 

Terminal block

holders.

If Noise suppressor is used,

 

Set Terminal block in Handle section

Field lead wires must be

route Noise suppressor’s lead

 

with each terminal positioned as follows:

tight in Motor housing.

wires between rib A and rib B.

*On Strain relief side, the terminal with which

 

Be careful not to put them on

 

the Lead wire of Power supply cord is connected

 

Noise suppressor, ribs A and B.

 

must be positioned.

 

*On Field side, the terminal with which the Field lead wire is connected must be positioned.

Page 16
Image 16
Makita HS7100 specifications Fig. D-4 HS6101 & HS7101 With Electric brake and LED light