Installation Instructions | Section 2 |
|
|
Self-Contained Electrical Wiring Connections
!Warning
These diagrams are not intended to show proper wire routing, wire sizing, disconnects, etc., only the correct wire connections.
All electrical work, including wire routing and grounding, must conform to local, state and national electrical codes.
Though wire nuts are shown in the drawings, the ice machine field wiring connections may use either wire nuts or screw terminals.
SELF CONTAINED ICE MACHINE 115/1/60 OR
L1 | L1 |
N=115V
OR
GROUND | GROUND |
|
ICE MACHINE
SV1258CONNECTIONS
SELF CONTAINED ICE MACHINE 208-230/3/60
L1
L2
L3
GROUND
ICE MACHINE
SV1190CONNECTIONS
SELF CONTAINED ICE MACHINE 230/1/50
L1
N
GROUND
ICE MACHINE
CONNECTIONS
SV1191
L1
L2
L3
GROUND
TO SEPARATE
FUSE/BREAKER
L1
N
GROUND
TO SEPARATE
FUSE/BREAKER. DISCONNECT ALL POLES.
For United Kingdom Only
As the colours of the wires in the mains lead of the appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:
•The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with
the letter E or by the earth ground symbol |
|
| or coloured green or green and yellow. | ||
|
|
|
|
|
|
•The wire coloured blue must be connected to the terminal which is marked with the letter N or coloured black.
•The wire coloured brown must be connected to the terminal which is marked with the letter L or coloured red.
| Part Number 000001114 |