Manitowoc Ice Q manual Maintenance, Section

Models: Q

1 56
Download 56 pages 32.31 Kb
Page 44
Image 44
Manual background

Maintenance

Section 4

 

 

Step 9 While components are soaking, use 1/2 of the cleaner/water solution to clean all foodzone surfaces of the ice machine and bin (or dispenser). Use a nylon brush or cloth to thoroughly clean the following ice machine areas:

Side walls

Base (bottom of the water trough)

Interior of the water trough

Evaporator cells and evaporator plastic parts - including top, bottom, and sides

Bin or dispenser

Ice machine top cover

Remove water trough drain plug and rinse all areas thoroughly with clean water. Reinstall water trough drain plug.

 

 

Clean/sanitize top,

 

 

bottom and sides

 

 

of evaporator.

 

 

Wipe bottom lip of

 

 

evaporator with a

 

 

sponge or cloth

 

 

soaked in cleaner

 

 

and then sanitizer

 

 

solution.

Step 10 Mix a solution of sanitizer and warm water.

Solution Type

Water

Mixed With

Sanitizer

6 gal. (23 l)

4 oz (120 ml) sanitizer

Step 11 Use 1/2 of the sanitizer/water solution to sanitize all removed components. Use a cloth or sponge to liberally apply the solution to all surfaces of the removed parts or soak the removed parts in the sanitizer/water solution. Do not rinse parts after sanitizing.

Step 12 Use 1/2 of the sanitizer/water solution to sanitize all foodzone surfaces of the ice machine and bin (or dispenser). Use a cloth or sponge to liberally apply the solution. Wipe all surfaces twice to ensure complete coverage with sanitizer solution. When sanitizing, pay particular attention to the following areas:

Side walls

Base (bottom of the water trough)

Interior of water trough

Evaporator cells and evaporator plastic parts - including top, bottom and sides

Bin or dispenser

Ice machine top cover

Do not rinse the sanitized areas. Remove the water trough drain plug and wipe with solution. When the sanitizer solution has drained from the trough, reinstall the water trough drain plug.

Step 13 Replace all removed components.

Step 14 Reapply power to the ice machine and place the toggle switch in the CLEAN position.

Step 15 Wait about two minutes or until water starts to flow over the evaporator. Add the proper amount of Manitowoc Ice Machine Sanitizer to the water trough by pouring between the water curtain and evaporator.

Model

Amount of Sanitizer

Q200 Q280 Q322 Q370

3 ounces (90 ml)

Q422 Q450 Q600 Q800

 

Q1000

 

Q1300 Q1600 Q1800

8.75 ounces (258 ml)

4-4

Part Number 000001114

Page 44