![B.Remove the ice thickness probe](/images/new-backgrounds/38713/3871383x1.webp)
Maintenance | Section 4 |
|
|
B.Remove the ice thickness probe
•Compress the hinge pin on the top of the ice thickness probe.
COMPRESS
HINGE PIN TO
REMOVE
SV3135
Ice Thickness Probe Removal
•Pivot the ice thickness probe to disengage one pin then the other. The ice thickness probe can be cleaned and sanitized at this point without complete removal. If complete removal is desired, disconnect the ice thickness control wiring from the control board.
C.Remove the water distribution tube
•Disconnect the water hose from the distribution tube.
1. LIFT UP | 3 | 2 |
| ||
2. SLIDE BACK |
| 1 |
3. SLIDE TO RIGHT
DISTRIBUTION
TUBE
THUMBSCREW
LOCATING
PIN
THUMBSCREW
SV1620
Water Distribution Tube Removal
•Loosen the two thumbscrews which secure the distribution tube.
•Lift the right side of the distribution tube up off the locating pin, then slide it back and to the right.
!Caution
Do not force this removal. Be sure the locating pin is clear of the hole before sliding the distribution tube out.
Disassemble for cleaning/sanitizing.
•Twist both of the inner tube ends until the tabs line up with the keyways.
•Pull the inner tube ends outward.
INNER TUBE
INNER TUBE | TAB |
|
KEYWAY
SV1211
Water Distribution Tube Disassembly
Part Number 000001114 |