B.Remove the ice thickness probe

Maintenance

Section 4

 

 

B.Remove the ice thickness probe

Compress the hinge pin on the top of the ice thickness probe.

COMPRESS

HINGE PIN TO

REMOVE

SV3135

Ice Thickness Probe Removal

Pivot the ice thickness probe to disengage one pin then the other. The ice thickness probe can be cleaned and sanitized at this point without complete removal. If complete removal is desired, disconnect the ice thickness control wiring from the control board.

C.Remove the water distribution tube

Disconnect the water hose from the distribution tube.

1. LIFT UP

3

2

 

2. SLIDE BACK

 

1

3. SLIDE TO RIGHT

DISTRIBUTION

TUBE

THUMBSCREW

LOCATING

PIN

THUMBSCREW

SV1620

Water Distribution Tube Removal

Loosen the two thumbscrews which secure the distribution tube.

Lift the right side of the distribution tube up off the locating pin, then slide it back and to the right.

!Caution

Do not force this removal. Be sure the locating pin is clear of the hole before sliding the distribution tube out.

Disassemble for cleaning/sanitizing.

Twist both of the inner tube ends until the tabs line up with the keyways.

Pull the inner tube ends outward.

INNER TUBEIce Thickness Probe Removal

INNER TUBE

TAB

 

KEYWAY

SV1211

Water Distribution Tube Disassembly

4-2