Manitowoc Ice Q Remote Condenser/Line Set Installation, 2-14, Installation Instructions, Section

Models: Q

1 56
Download 56 pages 32.31 Kb
Page 24
Image 24
Remote Condenser/Line Set Installation

Installation Instructions

Section 2

 

 

Remote Condenser/Line Set Installation

 

Remote Single

 

Ice Machine

Circuit

Line Set*

 

Condenser

 

Q490

JC0495

RT-20-R404A

Q690

JC0895

RT-35-R404A

Q890

 

RT-50-R404A

Q1090

JC1095

 

Q1390

JC1395

RL-20-R404A

Q1690

JC1695

RL-35-R404A

Q1890

JC1895

RL-50-R404A

*Line Set

Discharge Line

 

Liquid Line

RT

1/2" (12.7 mm)

 

5/16" (7.9 mm)

RL

1/2" (12.7 mm)

 

3/8" (9.5 mm)

 

 

Air Temperature Around the Condenser

Minimum

 

 

 

Maximum

-20°F (-28.9°C)

 

120°F (49°C)

sets of up to 50' (15.25 m). The serial tag on the ice machine indicates the refrigerant charge.

Additional refrigerant may be required for installations using line sets between 50' and 100' (15.25-30.5 m) long. If additional refrigerant is required, an additional label located next to the Model/Serial Numbers decal states the amount of refrigerant to be added.

IMPORTANT

EPA CERTIFIED TECHNICIANS

If remote line set length is between 50' and 100' (15.25-

30.5m), add 1.5 lb. (24 oz) (0.68 kg) of refrigerant to the nameplate charge.

Tubing length: ______________________________

Refrigerant added to nameplate: ________________

New total refrigerant charge: ___________________

Typical Additional Refrigerant Label

If there is no additional label, the nameplate charge is sufficient for line sets up to 100' (30.5 m). (See the chart below.)

REMOTE ICE MACHINES

REFRIGERANT CHARGE

Each remote ice machine ships from the factory with a refrigerant charge appropriate for installation with line

!Warning

Potential Personal Injury Situation

The ice machine contains refrigerant charge. Installation of the line sets must be performed by a properly trained and EPA certified refrigeration technician aware of the dangers of dealing with refrigerant charged equipment.

Ice Machine

Nameplate Charge

Refrigerant to be Added for

Maximum System Charge

(Charge Shipped in Ice Machine)

50'-100' Line Sets

(Never Exceed)

 

Q490

6 lb. (96 oz.)

None

6 lb. (96 oz.)

Q690

8 lb. (128 oz.)

None

8 lb. (128 oz.)

Q890

8 lb. (128 oz.)

None

8 lb. (128 oz.)

Q1090

9.5 lb. (152 oz.)

None

9.5 lb. (152 oz.)

Q1390

12.5 lb. (200 oz.)

1.5 lb. (24 oz)

14 lb. (224 oz.)

Q1690

15 lb. (240 oz.)

2.0 lb. (32 oz)

17 lb. (272 oz.)

Q1890

15 lb. (240 oz.)

2.0 lb. (32 oz)

17 lb. (272 oz.)

Before SN 110603336

 

 

 

Q1890

16 lb. (256 oz.)

2.0 lb. (32 oz)

18 lb. (288 oz.)

After SN 11060337

 

 

 

2-14

Part Number 000001114

Page 24
Image 24
Manitowoc Ice Q manual Remote Condenser/Line Set Installation, 2-14, Typical Additional Refrigerant Label, Section