Manitowoc Ice Q manual Section, Maintenance

Models: Q

1 56
Download 56 pages 32.31 Kb
Page 45
Image 45
Manual background

Section 4

Maintenance

 

 

Step 16 The ice machine will stop after the sanitize cycle (approximately 30 minutes). Place the toggle switch in the OFF position and disconnect power to the ice machine.

!Warning

Disconnect the electric power to the ice machine at the electric service switch box..

Step 17 Repeat step 6 for hand sanitizing.

Step 18 Mix a solution of sanitizer and warm water.

Solution Type

Water

Mixed With

Sanitizer

6 gal. (23 l)

4 oz (120 ml) sanitizer

Step 19 Use 1/2 of the sanitizer/water solution to sanitize all removed components. Use a cloth or sponge to liberally apply the solution to all surfaces of the removed parts or soak the removed parts in the sanitizer/water solution. Do not rinse parts after sanitizing.

Step 20 Use 1/2 of the sanitizer/water solution to sanitize all foodzone surfaces of the ice machine and bin (or dispenser). Use a cloth or sponge to liberally apply the solution. When sanitizing, pay particular attention to the following areas:

Side walls

Base (bottom of the water trough)

Interior of water trough

Evaporator cells and evaporator plastic parts - including top, bottom and sides

Bin or dispenser

Ice machine top cover

Do not rinse the sanitized areas. Remove the water trough drain plug and wipe with solution. When the sanitizer solution has drained from the trough, reinstall the water trough drain plug.

Step 21 Install the removed parts, restore power and place the toggle switch in the ICE position.

Part Number 000001114

4-5

Page 45
Image 45