Section 2

Installation Instructions

 

 

Installation Check List

Is the Ice Machine level?

Has all of the internal packing been removed?

Have all of the electrical and water connections been made?

Has the supply voltage been tested and checked against the rating on the nameplate?

Is there proper clearance around the ice machine for air circulation?

Has the ice machine been installed where ambient temperatures will remain in the range of 35° - 110°F (1.6° - 43.3°C)?

Has the ice machine been installed where the incoming water temperature will remain in the range of 35° - 90°F (1.6° - 32.2°C)?

Is there a separate drain for the water-cooled condenser?

Is there a separate drain for the bin?

Are the ice machine and bin drains vented?

Are all electrical leads free from contact with refrigeration lines and moving equipment?

Has the owner/operator been instructed regarding maintenance and the use of Manitowoc Cleaner and Sanitizer?

Has the owner/operator completed the warranty registration card?

Has the ice machine and bin been sanitized?

Is the toggle switch set to ice? (The toggle switch is located directly behind the front panel).

Is the ice thickness control set correctly? (Refer to Operational Checks to check/set the correct ice bridge thickness).

Additional Checks for Remote Models

Has the receiver service valve been opened?

Does the remote condenser fan operate properly after start-up?

Has the remote condenser been located where ambient temperatures will remain in the range of -20° - 120°F ( -29 - 49°C).

Is the line set routed properly?

Are both refrigeration lines to remote condenser run so they do not lay in water and are properly insulated?

Part Number 80-1620-3