Section 4

Maintenance

 

 

Evaporator Tray Removal

1.Remove the water trough.

2.Remove thumbscrew on left side of tray.

3.Allow left side of tray to drop as you pull the tray to the left side. Continue until the outlet tube disengages from the right side.

Drain Line Check Valve

The drain line check valve normally does not require removal for cleaning. Water loss from the sump trough will indicate removal and cleaning are required.

sv3154

1.Remove check valve and tube assembly.

A.Tip assembly to right until tubing disengages.

B.Lift up on assembly to remove.

2.Remove insulation from check valve assembly.

3.Remove vinyl tubing from top of check valve.

4.Soak in cleaner solution 10 minutes, and then flush with water to remove debris.

Part Number 80-1620-3

4-11

Page 51
Image 51
Manitowoc Ice S manual Evaporator Tray Removal, Drain Line Check Valve