Section 4

Maintenance

 

 

1.Water Curtain

A.Gently flex the curtain in the center and remove it from the right side.

B.Slide the left pin out.

STEP 2

STEP 1

SV3153

Water Curtain Removal

2.Ice Thickness Probe

A.Compress the hinge pin on the top of the ice thickness probe.

COMPRESS

HINGE PIN TO

REMOVE

SV3135

Ice Thickness Probe Removal

B.Pivot the ice thickness probe to disengage one pin then the other. The ice thickness probe can be cleaned at this point without complete removal. Follow Step C for complete removal.

!Warning

Disconnect the electric power to the ice machine at the electric service switch box.

C.Disconnect the ice thickness control wiring from the control board.

Part Number 80-1620-3

4-7

Page 47
Image 47
Manitowoc Ice S manual Water Curtain Removal Ice Thickness Probe, Ice Thickness Probe Removal