Marantz PMD325 How to use the RS-232Cconnector, Other Functions, English, •RS232C Connection

Models: PMD325

1 52
Download 52 pages 46.47 Kb
Page 47
Image 47
How to use the RS-232C connector

OTHER FUNCTIONS

How to use the RS-232C connector

This input/output connector (D-Sub 9-pin female) is used for RS-232C external control.

A straight cable available on the market can be connected to this connector to exercise external control and send status information.

Connector pin assignment

 

 

1

NC

6

9

2

TX

 

 

3

RX

 

 

4

NC

 

 

5

GND

1

5

6

NC

 

 

7

NC

 

 

8

NC

 

 

9

NC

RS232C Connection

Example: Reception Time Command (code 2011)

2

0

1

1

CR

0x32

0x30

0x31

0x31

0x0d

 

 

 

 

 

When transmitting commands consecutively, put more than 100ms blank between commands.

Received command data

Command

Code

 

Command

Code

0

2000

 

Pitch Down Start

2039

 

 

 

 

 

1

2001

 

Pitch Down Stop

203901

 

 

 

 

 

2

2002

 

Program

2041

 

 

 

 

 

3

2003

 

AMS

2043

 

 

 

 

 

4

2004

 

Open/Close

2045

 

 

 

 

 

5

2005

 

Pause

2048

 

 

 

 

 

6

2006

 

Cancel

2049

 

 

 

 

 

7

2007

 

Fast Backward Start

2050

 

 

 

 

 

8

2008

 

Fast Backward Stop

205001

 

 

 

 

 

9

2009

 

Fast Forward Start

2052

 

 

 

 

 

Time

2011

 

Fast Forward Stop

205201

 

 

 

 

 

Recall/Scroll

2015

 

Play

2053

 

 

 

 

 

Random

2028

 

Stop

2054

 

 

 

 

 

Repeat

2029

 

A-B

2059

 

 

 

 

 

Next

2032

 

Display (Dimmer)

2071

ENGLISH

PMD325

Transmit Data

2

Receive Data

3

Ground

5

D-Sub 9 Pin

(male)

Typical HOST

2Rx Data

3Tx Data

5 Ground

D-Sub 9 Pin

(female)

Previous

2033

 

Menu

2082

Index +

2034

 

Enter

2087

 

 

 

 

 

Index -

2035

 

Text

2088

 

 

 

 

 

Pitch Reset

2037

 

Quick Replay

205304

 

 

 

 

 

Pitch Up Start

2038

 

Cue

205910

 

 

 

 

 

Pitch Up Stop

203801

 

 

 

Status transmission

The wiring requirements for a 9 pin to 9 pin serial connection, are a male to female straight cable.

RS-232C physical specifications

Cable

Straight cable

 

 

Baud rate

9600 bps

 

 

Data bits

8 bits

 

 

Parity bit

None

 

 

Stop bit

1 bit

 

 

Flow control

None

 

 

Command reception

The command packets have a data length of 5, 6 or 7 bytes. ASCII codes from 0x00 to 0x7f are used to receive serial data. At the transmission end, therefore, take steps to convert the ASCII codes into HEX data to set the data in the data packets. CR (0x0d) is added as the data packet delimiter.

The status packets have a fixed data length of 4 bytes. ASCII codes from 0x00 to 0x7f are used to transmit serial data. For this reason, the ASCII codes are converted into HEX data before the data is set in the data packets and transmitted. CR (0x0d) is added as the data packet delimiter.

Example 1: Transmission Power On (code PWON)

P

W

O

N

CR

0x50

0x57

0x4f

0x4e

0x0d

Transmitted status data

Status

Code

Description

 

 

 

Power On

PWON

Transmitted when the power is turned on.

 

 

 

Tray Open

TROP

Transmitted upon completion of tray open.

 

 

 

Tray Close

TRCL

Transmitted upon completion of tray close.

 

 

 

TOC Error

TOCE

Transmitted when a TOC read error has occurred.

 

 

 

TOC Reading

TOCR

Transmitted when TOC read is started.

 

 

 

No Disc

NODI

Transmitted when “No disc” is detected.

 

 

 

Stop

STOP

Transmitted when the disc has stopped.

 

 

 

 

 

Transmitted along with the track number (xxx)

Play

Pxxx

when play is started; also transmitted when

 

 

the track number is changed during play.

 

 

 

Pause

Axxx

Transmitted along with the track number (xxx)

 

 

when the pause status is established.

 

 

 

Fast Forward

FFON

Transmitted when Fast Forward is started.

 

 

 

Fast Backward

RWON

Transmitted when Fast Backward is started.

 

 

 

Repeat Off

RPOF

Transmitted when Repeat Off is set.

 

 

 

Repeat All

RPAL

Transmitted when Repeat All is set.

 

 

 

Repeat One

RPON

Transmitted when Repeat One is set.

 

 

 

Repeat A

RPA-

Transmitted when Repeat A is set.

 

 

 

Repeat AB

RPAB

Transmitted when Repeat A-B is set.

 

 

 

End Warning

ENDW

Transmitted when End Warning is started.

 

 

 

43

Page 47
Image 47
Marantz PMD325 How to use the RS-232Cconnector, Other Functions, English, •Connector pin assignment, •RS232C Connection