Planning and Preparation
Network Adapter Configurations
Depending upon your specific switchbay and blade
To maximize the availability of the redirected links, different switches should be used to connect the CoServers to the external network. To mini- mize utilization of the external network by the CoServer links, both CoServ- ers should use the same internal switch for a CSLink connection. Routing a CSLink connection through the same switch will confine all associated traf- fic to that switch. Several recommended network configurations using 4, 3, and 2 network adapters are shown in the following tables.
TABLE 1. 4 NIC Configuration
Function | CoServer 1 | CoServer 2 | Comment |
|
|
|
|
CSLink 1 | Switchbay 1 | Switchbay 1 | Internal Bandwidth |
|
|
|
|
CSLink 2 | Switchbay 2 | Switchbay 2 | Internal Bandwidth |
|
|
|
|
Redirected | Switchbay 3 | Switchbay 4 | Redundant External Connection |
|
|
|
|
Manage | Switchbay 4 | Switchbay 3 | Redundant External Connection |
|
|
|
|
TABLE 2. 3 NIC Configuration
Function | CoServer 1 | CoServer 2 | Comment |
|
|
|
|
CSLink 1 | Switchbay 1 | Switchbay 1 | Internal Bandwidth |
|
|
|
|
Redirected | Switchbay 2 | Switchbay 3 | Redundant External Connection |
|
|
|
|
CSLink 2 | Switchbay 3 | Switchbay 2 | Exposed network utilization |
|
|
| Requires network routed IP |
|
|
| addresss |
TABLE 3. 3 NIC Alternate Configuration
Function | CoServer 1 | CoServer 2 | Comment |
CSLink 1 | Switchbay 1 | Switchbay 1 | Internal Bandwidth |
|
|
|
|
Redirected | Switchbay 2 | Switchbay 3 | Redundant External Connection |
|
|
|
|
Manage | Switchbay 3 | Switchbay 2 | Redundant External Connection |
|
|
|
|
8 | Marathon Technologies Corporation |