If necessary a sensor can be erased from the memory of the base station (e.g. code changed when batteries were changed). When you want to
To erase a registered sensor:
Every time you press a key you hear a short confirmation beep.
1.Set the mode switch to the INSTALL position: All indicators of occupied zones come on
2.Key in your 4 digit PIN code (factory default [0000] refer to 5.8)
3.Press key number 8
4.Press ENTER
5.Enter the required zone (1…16, e.g. press 2 for zone 2, press 1 + 5 for zone 15):
6.Press ENTER
7.Reset the mode switch to the RUN 1 or RUN 2 position: Zone indicators go out
5.10 ERASING OF ALL SENSORS
In case it is required, you can reset the base station to the factory default settings. However, your PIN and option settings remain the same. Every time you press a key you hear a short confirmation beep.
1.Set the mode switch to the INSTALL position: All indicators of occupied zones come on
2.Key in your 4 digit PIN code (factory default [0000] refer to 5.8)
3.Press key number 0
4.Press ENTER
5.Reset the mode switch to the RUN 1 or RUN 2 position: Zone indicators go out
22 | MARMITEK |