DISARM: Switches off the security system.

 

 

 

 

 

ALL LAMPS ON: for switching on all lamp

 

 

 

 

 

modules with one press of a button.

 

 

 

 

 

ALL LAMPS OFF: for switching off all (lamp and

3

 

 

 

 

appliance) modules with one press of a button.

 

 

 

 

MODE SWITCH IN POSITION 1:

 

 

 

 

 

 

 

 

 

 

1…8: For controlling Marmitek X-10 Home

 

 

 

 

 

Automation modules with corresponding address

7

 

 

 

 

(unit code 1 t/m 8).

 

 

 

 

 

MODE SWITCH IN POSITION 2:

 

 

 

 

 

9…16: For controlling Marmitek X-10 Home

 

 

 

 

 

Automation modules with corresponding address

 

 

 

 

 

(unit code 9 t/m 16).

 

 

 

 

 

6. HOUSE CODE SWITCH

 

 

 

 

 

Used for setting the system address. For proper

 

 

 

4

 

communication, all code switches of the system

 

 

 

 

components have to set to the same House Code.

 

 

 

5

 

7. TEXT WINDOW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

On the piece of paper behind the plastic cover of

6

 

 

 

 

 

 

the text window, you can note which Home

 

 

 

 

 

 

 

 

 

 

Automation modules can be controlled with each

key. (e.g. living room lamp, TV, garden lights, etc.).

8.BATTERY COMPARTMENT (BACK COVER) INSTALLATION:

1. PLACING THE BATTERIES

IMPORTANT: When placing the batteries, make sure the switch is not in position 2!

Open the battery compartment on the back of the remote control and place the batteries (4 x AAA, preferably use alkaline batteries). Make sure you observe the instructions in the battery compartment. Replace the battery cover.

2.ACTIVATION OF THE SH624 (install mode) Press the PANIC key until the control indicator comes on. Set the mode switch to the SEC position. Make also sure that the House Code is on the same letter code as the base station (behind the cover).

4.7 LM12 LAMP MODULE (OPTIONAL FOR MS9470)

Lights with a power rating between 40W minimum and 300W can be connected to the lamp module. Do not connect any other load -like household equipment or CFL lights- to the module to avoid damage to your equipment and lamp module. Special modules exist for other loads. The lights connected to the lamp module can be activated by the remote controls. Also, when an alarm situation occurs, the lights will flash. During the delay time when arming the system, these lights will also be on. For more information about what is possible, please refer to 6.8.

1. HOUSE CODE SWITCH

Used for selecting the system address. All House Code Switches of the system components need to be set to the same code.

2. UNIT CODE SWITCH

Used for setting the module number. When you set the Unit Code on a module to number 3, you can switch the module on and off with key 3 on the SH624 system remote.

3. PLUG SOCKET

For connecting lamps which you want to control with the module.

4. FUSE

The fuse protects the lamp module against overload. In case of a defective fuse, only replace this with one of the same electrical ratings.

INSTALLATION LM12

Plug the lamp module in a spare wall socket and plug the lights you want to control (40-300W) into the socket of the lamp module.

3

4

1

2

*Plug type may vary