5.6 DELAY TIMES

ARMING

When arming the security system by means of the remote controls KR21 or SH624 in the ARM AWAY mode, the system will arm with a instantaneously (factory default). In case you want to arm the system delayed, you can program the base station for a delay. (N.B.: Arming the system by means of the ARM AWAY button on the base station, always will result in a delayed arming of the system).

ALARM SENSORS

When the security system is armed, sensors can activate the system either instantaneously or with a delay. This depends on the settings of the SC2800 base station and the switch setting of the sensors. Refer to the list below for a complete overview.

Every time you press a key you hear a short confirmation beep.

1.Set the mode switch to the INSTALL position: All indicators of occupied zones come on

2.Key in your 4 digit PIN code (factory default [0000] refer to 5.8)

3.Press key number 5

4.Press ENTER

5.Press 0 for instantaneous alarm or

Press 1 for delayed alarm

6.Reset the mode switch to the RUN 1 or RUN 2 position: Zone indicators go out

OVERVIEW DELAY TIME:

 

SC2800 base station operation “instantaneous alarm”

 

Arming of the system with remote controls:

Instantaneous

Arming of the system with ARM AWAY button of base station:

Delay of one minute

Arming of the system with ARM HOME button of base station:

Instantaneous

Alarm activation by a DS10 door/window contacts:

Instantaneous when switch is in MIN position,

 

30 seconds when in MAX position

Alarm activated by an MS10 motion sensors:

Instantaneous

SC2800 base station operation “delayed alarm”

 

Arming of the system with remote controls:

Arming of the system with ARM AWAY button of base station: Arming of the system with ARM HOME button of base station: Alarm activation by a DS10 door/window contacts:

Alarm activated by an MS10 motion sensors:

Delay of one minute Delay of one minute Delay of one minute

Instantaneous when switch is in MIN position, 30 seconds when in MAX position

Delay of 30 seconds

MS9470/MS9770/MS9970