4.2

THE SC2800

BASE STATION

1. PANIC

When pressed, this red button initiates an immediate alarm.

 

 

12

1

 

 

 

6

 

2

 

13

 

 

3

9

 

 

 

7

8

14

 

 

15

2. ARM HOME

4

5

16

Alarm function when being at home. Only door and window sensors (no motion sensors) are activated.

3. ARM AWAY

All sensors are activated.

4. BYPASS

When you want to arm the system and one of the sensors is reporting a problem (e.g. window is still open, battery low, etc.), you can choose to arm the system without activating this particular sensor. As long as you can hear the dual error tone error, you have the option to press the “bypass” button and arm the system again. The zone indicator of that sensor is now flashing rapidly.

10

11

17

23

18

19

20

21

22

Once the error condition is corrected (e.g. window closed), the bypass will be automatically removed and the sensor becomes part of the total system again.

5. DISARM

Disarms the system after entering your personal identification code (PIN).

6. SYSTEM INDICATORS

RECORD – Lights when during recording and playing the personal security message. JAMMING- Indication that a strong interfering signal is detected.

ARM- Lights when the system in armed.

BATTERY LOW- Indication that the back up battery of the base station needs to be replaced. POWER- Indication for proper operation of the PS500. Lights during normal operation.

7. KEYBOARD

To program and operate the security system.

8. UNIT ON/UNIT OFF

For operating Marmitek X-10 Home Automation Modules (like LM12 Lamp Module). Enter the unit code of the module on the keyboard. Then use this key to switch this module on or off.

9. BRIGHT/DIM

For controlling the brightness of lights connected to a specific lamp module. Enter the unit code of the module on the keyboard and then use this key to brighten or dim the lights.

10. ALL LIGHTS ON/OFF

To switch on all lamp modules in the system or to switch off all modules (lamp and appliance modules), regardless the address.

11. MICROPHONE

Very sensitive microphone for:

recording a personalised alarm message

“listen-in” to the protected premises via the telephone line during an alarm situation

12.RUN 1, RUN 2, INSTALL, THERM SWITCH RUN 1 – For normal alarm operation.

RUN 2 – For normal alarm operation. When in disarmed mode, the base station will give a pleasant sounding tone when a door or window is opened (access control).

INSTALL – Position for installing sensors and for changing system settings.

THERM - For use with Marmitek X-10 Wireless Thermostats. Thermostat functions are described in the manual of the thermostat.

6