PRODUCT SPECIFICATIONS

Shock and Vibration

PARAM ETER

OPER AT ING

N ON- OPER AT ING

 

 

 

 

Mechanical Shoc k

30 Gs, 2.0 ms , no errors

300

Gs, 2.0 ms , no damage

 

 

 

Rotational Shoc k

 

20,000 Rad/sec ,0.5 to 1.0 ms , no d

 

 

 

Random Vibration

10 to 45 Hz at 0.004 G2/Hz

PSD :

 

48 to 62 Hz at 0.008 G2 /Hz

10 Hz at .05 G2/Hz

 

65 to 300 Hz at 0.004 G2 /Hz

20 Hz at .055 G2 /Hz,

 

301 to 500 Hz at 0.0006 G 2 /Hz

300

Hz at .05 G2 /Hz

 

no errors

301

Hz at .0014 G2/Hz

 

 

500

Hz at .001 G2/Hz

 

 

760

Hz at .001 G 2/Hz

 

 

877

Hz at .003 G2/Hz

 

 

1000 Hz at .001 G2/Hz

 

 

1570 Hz at .001 G2/Hz

 

 

2000 Hz at .0001 G2/Hz

Swept Sine Vibration

 

 

 

10 to 300 Hz

1 G (0 to peak ) amplitude, 1 octave per minute

 

 

Reliability Specifications

Annual Return Rate

 

< 0.5%

Annual Return Rate (ARR) indicates the average against products shipped.

 

ARR includes all reasons for returns (failures, handling damage, NDF), but

 

does not include inventory credit returns.

Quality Acceptance Rate

 

<1,000 DPPM

The quality acceptance rate indicates the percentage of Maxtor products

 

successfully installed by our customers, and/or the number of defective parts

 

per million (DPPM) encountered during the entire installation process.

Start/Stop Cycles

 

>50,000

This indicates the average minimum cycles for reliable start/stop function.

Load/Unload Cycles

 

>100,000

This indicates the average minimum cycles for reliable load/unload function.

Data Reliability

 

<1 per 10E14 bits read

Data errors (non-recoverable). Average data error rate allowed with all error

 

recovery features activated.

Component Design Life

 

5 years (minimum)

Component design life is defined as a.) the time period before identified

 

wear-out mechanisms impact the failure rate, or b.) the time period up to the

 

wear-out point when useful component life expires.

3 – 4

Page 18
Image 18
Maxtor 2B015H1, 2B010H1, 2B020H1 Shock and Vibration, Reliability Specifications, Param Eter Oper AT ING ON- Oper AT ING