INTERFACE COMMANDS

InitializationCommands

Identify Drive

Allows the host to receive parameter information from the drive.

When the command is received, the drive:

1.Sets BSY,

2.Stores the required parameter information in the sector buffer,

3.Sets the DRQ bit and

4.Generates an interrupt.

The host may then read the information out of the sector buffer. Parameter words in the buffer follow. Note that all reserved bits or words should be zeroes.

W OR D

CONT ENT DESC RIPTION

0

General configuration

 

15 = device (0 = ATA device, 1 = ATAPI)

 

14 -8 = retired

 

7, 1 = removable media device

 

6, 1 = not removable controller and/or device

 

5-3 = retired

 

2 = response incomplete

 

1 = retired

 

0 = reserved

1

Number of logical cylinders

2

Reserved

3

Number of logical heads

4-5

Retired

6

Number of logical sectors per logic al track

7-8

Reserved

9

Retired

10 - 19

Drive serial number (20 ASCII characters )

20 - 21

Retired

22

Obsolete

23 - 26

F irmware revision (8 ASCII characters )

27 - 46

Model number (40 ASCII characters )

47

Maximum number of sectors that c an be transferred per interrupt on read and write multiple commands

48

Reserved

49

C apabilities

 

15 - 14 = reserved

 

13 = s tandby timer (1 = values as specified in this s tandard are s upported, 0 = values are Maxtor specific )

 

12 = reserved (advanc ed PIO mode support)

 

11, 1 = IORD Y supported, 0 = IORDY may be supported

 

10, 1 = IORDY can be disabled

 

9-8 = shall be set to one. Us ed by Identify Packet Device comm and .

 

7-0 = not us ed

7 – 10

Page 50
Image 50
Maxtor 2B020H1, 2B015H1, 2B010H1 manual InitializationCommands, Or D ENT Desc Ription