PROGRAMMING

“STRT DAY” - Day of Week Start Setting

This function is used to set the day(s) of the week to start selection blocking.

Press key number 4 and “XXXXXX#” will show on the display, where XXXXXX will be the day of the week (i.e. MONDAY, TUEDAY, WEDDAY, THUDAY, FRIDAY, SATDAY, SUNDAY, EVR DAY) and # is 0 = disable, 1 = enable.

With the display showing the day you wish to set press key number 4.

The # will start blinking. Press key number 2 or 3 to scroll between “XXXXXX0” and “XXXXXX1.” Press key number 4 with the display showing the setting you wish to use.

Display will return to “XXXXXX#’.

Press key number 2 to scroll to the next day to set or press key number 1 to return to “STRT DAY”. Press key number 2 to scroll to “STRT HR”.

“STRT HR” - Start Hour and Minute Setting

This function is used to set the hours and minutes to start selection blocking.

Press key number 4 and “hhmm” will show on the display, where hh is the hour (military time) and mm is the minute. “hh” will be blinking, indicating the hour setting may be changed.

Press key number 2 to scroll from 00 to 23. With the display showing the hour you wish to start selection blocking, press key number 4. “mm” will then start blinking, indicating the minute setting may be changed.

Press key number 2 to scroll from 00 to 59. With the display showing the minute you wish to start selection blocking, press key number 4. The display will return to “STRT HR”.

Press key number 1 to return to “STRT TIM”. Press key number 2 to scroll to “STOP TIM”.

“STOP TIM” - Stop Selection Blocking Routine

This function is used to set the day(s) and times to stop selection blocking.

Press key number 4 and “STOP DAY” will show on the display.

“STOP DAY” - Day of Week Stop Setting

This function is used to set the days of the week to stop selection blocking and can be set in the same manner as Day of Week Start Setting.

“STOP HR” - Stop Hour and Minute Setting

This function is used to set the hours and minutes to stop selection blocking and can be set in the same manner as Start Hour and Minute Setting.

Press key number 1 to return to “STOP TIM”. Press key number 2 to scroll to “SELECT”.

“SELECT” - Selection To Be Affected By Blocking

This function is used to set selection(s) which will be blocked during certain periods of the day. Press key number 4 and “SELA1#” will be displayed, where # is the current setting for the selection number displayed. 0 = disabled; 1 = enabled.

Press key number 2 to scroll to the key number setting you desire to change.

Press key number 4 with the key number showing you wish to change (i.e. SELA1#) and the # will start blinking.

Press key number 2 or 3 to scroll between SELA1 0 and SELA1 1. Press key number 4 with the display showing the setting you wish to use. Display will return to SELA1#.

Press key number 1 to return to “SELECT”. Press key number 2 to scroll to “LIGHT”.

21 of 90

Page 21
Image 21
Maytag DN5000, DN3000 manual Strt DAY Day of Week Start Setting, Stop TIM Stop Selection Blocking Routine

DN5000, DN3000 specifications

The Maytag DN3000 and DN5000 are two robust commercial dishwashers designed to handle the rigorous demands of busy kitchens, making them ideal for restaurants, hotels, and catering operations. What sets these models apart is their combination of efficiency, performance, and durability, which are essential for maintaining high standards of cleanliness and sanitation.

Both the DN3000 and DN5000 feature an advanced wash system that ensures thorough cleaning of dishes, pots, pans, and utensils. The powerful wash pumps are designed to deliver optimal spray coverage, while the stainless steel construction enhances durability and corrosion resistance. This translates into longer-lasting equipment that can withstand the wear and tear of a high-volume environment.

In terms of capacity, the DN3000 can handle up to 300 racks per hour, while the DN5000 steps up the game with a capacity of 500 racks per hour. This makes the DN5000 particularly suited for establishments with heavy dishwashing loads, where speed and efficiency are paramount. Both models are equipped with a built-in booster heater that ensures optimal water temperatures for effective sanitization, which is critical for health and safety compliance.

User-friendly controls are another highlight of these dishwashers. The intuitive digital display allows operators to easily select wash cycles, monitor cycle progress, and troubleshoot issues. Additionally, both models feature automatic drain systems that help prevent clogs and reduce maintenance interruptions.

Energy and water efficiency are also key characteristics of the Maytag DN3000 and DN5000. These dishwashers are designed to minimize water consumption, making them environmentally friendly options that can help lower operational costs. With their ENERGY STAR certification, they meet energy-efficiency guidelines set by the U.S. Environmental Protection Agency.

Both models also come with customizable rack options to maximize washing effectiveness for various types of dishware, from flat dishes to larger pots and pans. Safety features like lockable controls and built-in safety interlocks further enhance operability, providing peace of mind for kitchen staff.

In summary, the Maytag DN3000 and DN5000 dishwashers are engineered for optimal performance in the fast-paced commercial kitchen setting. With their impressive capacity, advanced wash technology, user-friendly controls, and energy efficiency, these models are reliable choices for any food service operation looking to maintain high standards of cleanliness and efficiency.