!WARNING

To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and discharge capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures require power to be connected. Ensure all ground wires are connected before certifying unit as repaired and/or operational.

Inner Door Panel

Removal of the Inner Door Panel will allow access to the Microprocessor Board, Door Switches, Detergent / Rinse Aid Dispenser, and Vent Assembly.

Removal

1.Disconnect power to the machine.

2.Open the Dishwasher door.

3.Remove the 11 Torx™ screws along the sides and top of the Inner Door Panel.

4.Separate the Inner Door Panel from the Outer Door.

Detergent / Rinse Dispenser Mechanism and Reservoir

Checking Operation

1.Disconnect power to the machine.

2.Remove the Inner Door Panel. (See paragraph Inner Door Panel removal).

3.Snap the Detergent Door shut.

4.Gently lift the lever of the dispenser mechanism until a click is herd. The Detergent Door releases. Re- lease the lever.

5. Disconnect wires from the Vent and Dispenser Wax

5. Lift the lever again. Now the actuator will lift the Rinse

Aid Plunger.

 

Motors before pulling the Inner Door Panel away

 

 

from the Dishwasher.

 

 

 

IMPORTANT: When replacing Inner Door Panel, remove

 

 

Inner Door reinforcement, Bottom Seal and install on

 

 

new panel.

 

 

 