Top Wash Arm

Service and Disassembly Procedures

!WARNING

To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and discharge capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures require power to be connected. Ensure all ground wires are connected before certifying unit as repaired and/or operational.

Door Spring and Component Replacement Over Pressure Filter

NOTE: Always point spring hooks toward the Dishwasher.

1.Disconnect power to the machine.

2.Remove Dishwasher from cabinets.

3.Attach Door Cable Link to Door Hinge.

4.Attach Cable to Cable Link.

5.Route Cable under Cable Roller.

The purpose of the Over Pressure Filter is to filter sediment missed by the lower filter rather than circulating it back through the wash.

Removal

1.Spread locking tabs.

2.Rotate filter down and remove from manifold.

Top Wash Arm

6.Attach Cable to short hook of Spring.

7.Place large hook end of Spring into Spring Adjustment

Removal

1. Spread locking tabs and remove Wash Arm Retainer.

Bracket in proper location.

 

 

NOTE: To replace Cable Bracket, remove 2 Torx™

 

 

screws securing bracket to frame. See

 

 

procedure above for reassembly of Spring and

 

Cable.

 

 