Using the calibration procedure

Calibrating the loudspeakers

As you run the calibration procedure the name of each loudspeaker is shown on the front panel display. The on-screen display also provides additional text explaining what to do, and sample displays are reproduced in the following sections for reference. For information about setting up the on-screen display see On-screen display, page 30.

Using a Sound Pressure Level meter

Although you can perform the calibration procedure by ear, it is recommended that you perform the tests using a Sound Pressure Level meter, available fairly cheaply from Tandy/Radio Shack, or your Meridian dealer may be able to lend you one.

Set the Sound Pressure Level meter to C weighted, and slow. Take readings from the listening position, holding the meter vertical at head height.

To start the calibration procedure

Put the surround controller into standby by pressing the Off key.

Press and hold the front panel Off key for at least five seconds.

Calibration

The display shows:

The on-screen display shows:

42