15. Technical Specifications
Voltage V230(150Hz) 110 (150 Hz)
Current draw A 5.8 11.9
Fuse protection A 10 (time-lag) 16 (time-lag)
Motor capacity (power input P1, S6 20% - 5 min) kW 1.3 1.3
Protection class IP 20 20
Degree of protection II II
Saw blade speed min-1 5500 4720
Cutting speed m/s 55 60
Saw blade diameter (outer) mm 210 210
Arbor bore mm 30 30
Dimensions
Machine in packing
Length / width / height
Saw ready to operate, rotating table in 0°-position
Length / width / height
mm
mm
645/ 540 / 375
1020/ 508/ 470
645/ 540 / 375
1020/ 508/ 470
Maximum workpiece cross section
Standard cross cuts
width / height
Mitre cuts (rotating table 45°)
width / height
Bevel cuts (track arm holder 45° left)
width / height
Compound mitre cuts (rotating table 45° / track arm holder 45 ° left)
width / height
mm
mm
mm
mm
255/ 60
177/ 60
255/ 30
177/ 30
255/ 60
177/ 60
255/ 30
177/ 30
Weight
Machine in packing
Machine ready to work kg
kg 20.5
17 20.5
17
Permissible ambient temperature for operation
Permissible temperature for transport and storage °C
°C 0 to + 40
0 to + 40 0 to + 40
0 to + 40
Noise emission according to EN ISO 3744
Sound power level LWA
Sound pressure level at operator ear LPA
dB (A)
dB (A) 109
96 109
96
Effective value of weighted acceleration
(vibration at handle) m/s2< 2.5 < 2.5
Dust extractor (not included in standard delivery)
Suction port diameter
Minimum air volume flow
Minimum vacuum at suction port
Minimum air speed at suction port
mm
m3/h
Pa
m/s
43,5
550
740
20
43,5
550
740
20
Flange laser
Max. output power
Wave length
Laser product class
Batteries
mW
nm
3×type
1.0
650
2
AG13 / LR44
1.0
650
2
AG13 / LR44
This machine is specially designed for the high momentary loads of crosscutting. The motor reaches the stated power of 1200 watts
at S6 20% 5 min (intermittend periodic duty-type with starting). This means that this saw can be operated for 1minute at full-load
rating (1200 watts) within a 5 minute operating period. The motor has to deliver these 1200 watts only under extreme load condi-
tions - during normal crosscutting it is subjected to much lower loads. With lower loads the duty cycle of the motor increases sub-
stancially. Thus, when used as specified, because of its high reserve capacity, overheating or overloading of the motor is not possi-
ble.