Miscellaneous Problem Troubleshooting Table

SYMPTOM

CAUSE

 

REQUIRED ACTION

 

 

 

 

 

 

1.

Remove fluorescent tube from its sockets. If you

Marquee lamp is intermittent

Faulty fluorescent

 

find cracks or darkened ends, install new lamp.

or non-functional

tube

 

Clean tube.

 

 

2.

Check continuity of both fluorescent tube

VGM (video game machine)

 

 

filaments.

starts and plays normally

 

3.

Verify that fluorescent tube operates by placing it

 

 

 

in working VGM.

 

Faulty lamp fixture

1.

Verify that lamp pins make good connection with

 

 

 

socket contacts.

 

 

2.

Check ballast for continuity.

 

Faulty wiring

1.

Measure fluorescent lamp AC voltages. Check

 

 

 

wiring and connector continuity from AC power

 

 

 

chassis to lamp assembly.

 

 

2.

If you find faulty wiring, repair or replace it.

 

 

1.

Check bottom and rear of cabinet for blocked

VGM operates normally

Obstructed fan

 

airflow.

 

 

2.

Move VGM away from sources of heat.

Cabinet becomes warm after

 

3.

Turn off VGM power. Remove dust from vent

several hours of use

 

 

holes with high-power vacuum cleaner.

 

Faulty wiring

1.

Check fan wiring and connectors.

 

 

2.

If you find faulty wiring, repair or replace it.

 

Faulty fan

1.

Check operation of all fans, including power

 

 

 

supply fan.

 

 

2.

If fan is faulty, replace it.

 

 

1.

Check any assembly (RAM, ROM, Battery, etc.)

Error messages appear on

Faulty hardware

 

identified in error messages.

screen

 

2.

Replace faulty parts.

 

 

3.

Call your authorized distributor for help with

 

 

 

unresolved screen messages.

Fan Location and Mounting

Troubleshooting 6-12

Page 114
Image 114
Midway 4-Player 25 Dedicated Video Game manual Miscellaneous Problem Troubleshooting Table