Plumbing (may vary by model)
The machine must be connected to the water supply by a licensed plumber in accordance with local and national regulations. The water being used should have the drinking water standards of the respective country where the machine is used.
–All units and systems used to deliver the water to the appliance must conform with the requirements of the respective country.
–The machine is designed to be plumbed to a cold water connection.
Connecting to the water supply
^Disconnect the machine from the electrical supply.
–The
needed. If not present, have a water valve installed by a licensed plumber.
–The water valve must be accessible after installation.
–Water pressure
Maximum: 145 psi, if higher, install a pressure reduction valve.
–Suitable 1/4" tubing or copper piping must be supplied for plumbing.
–To ensure the best ice cube quality, the maximum length of the tubing or copper pipe should not exceed 4 ft. 11" (1.5 m). If too much water remains in the tubing the quality could be affected.
^Remove the cover cap a from the solenoid valve b.
^Install the compression fitting c with the sealing ring d on the solenoid valve b.
^Attach the copper line e to the compression fitting c.
^Secure the copper line to the appliance using cable clips f.
38