Miele KFN 8992 SD ED, KFN 8993 SDE ED installation instructions Installing the appliance

Models: KFN 8993 SDE ED KFN 8992 SD ED

1 48
Download 48 pages 59.78 Kb
Page 46
Image 46
Installing the appliance

Installing the appliance

The air intake and outlet must not be blocked or covered in any way. They also need to be dusted/cleaned on a regular basis.

If the appliance is installed next to a wall c, a gap of approx. 50 mm (2") is needed on the hinge side between the wall and the appliance b, so that the appliance doors can be completely open, with space for the handle.

The appliance can be installed in any kitchenette. To match the appliance to the height of the kitchenette, a suitable adapter cabinet a can be installed over the appliance.

A ventilation gap of at least 50 mm (2") depth must be left behind the applicance. The gap between the appliance/adapter cabinet and the room ceiling must be at least 40 mm (1 9/16"), so that warm air can escape without obstruction. Otherwise the appliance has to work harder, which results in increased energy consumption. The greater the ventilation cross-section, the more energy-efficient the appliance can be.

46

Page 46
Image 46
Miele KFN 8992 SD ED, KFN 8993 SDE ED installation instructions Installing the appliance