Calibrating the sensor switches

Before using for the first time

Calibrating the sensor switches

Automatic calibration

To ensure trouble free operation, the sensors

need to be recalibrated after installation and each time the electricity supply fails, e.g. after a power cut.

The safety lock indicator lamp lights up during automatic calibration, and the hob cannot be switched on.

adjust themselves constantly whilst the hob is in use.

If automatic calibration is unsuccessful, an A lights up in the cooking zone display on the left and right at the front, and an F lights up on the left at the back. Numbers light up in the cooking zone display on the right at the back and in the Timer/Memory display.

If this happens, recalibration will have to be carried out manually.

Manual calibration

^Make sure that there is no direct light (from the sun or from an artificial source) falling onto the hob. The area surrounding the hob must not be too dark, nor should the relationship between light and shade be constantly changing.

^Make sure that there is nothing covering the sensors or the hob. Take any pans off the hob and wipe away any food deposits.

^Interrupt the power supply to the hob for approx. 1 minute.

Reconnect the hob to the electricity supply. The electronic unit will reset the sensitivity levels of the sensors.

If this does not solve the problem, please call the Miele Service department.